Every required area of refuge shall have direct access to a stairway complying with Sections 1007.3 or an elevator complying with Section 1007.4....
Search Results "Elevator Pit"
Commonly Searched Documents
-
1007.6 Areas of refuge
-
1(2) Site impracticality
Covered multifamily dwellings with elevators shall be designed and constructed to provide at least one accessible entrance on an accessible route, regardless of terrain or unusual characteristics...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
III-5.4200 Professional office of a health care provider
The ADA's elevator exemption does not apply to buildings housing the offices of a health care provider....
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
408.1 General
Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
408.1 General
Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker.
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker.
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker.
-
13.1 Q. Are the public and common use areas of a newly constructed development that consists entirely of buildings having four or more multistory townhouses, with no elevators, required to be accessible?
Multistory townhouses, provided that they meet the definition of multistory in the Guidelines, are not covered multifamily dwellings if the building does not have an elevator....
-
§ 35.151(c)(2)
before March 15, 2012, then new construction and alterations subject to this section may comply with one of the following: The 2010 Standards, UFAS, or the 1991 Standards except that the elevator...
-
4.10.6* Door Protective and Reopening Device
Elevator doors shall open and close automatically....
-
Accessible Routes [§402]
Accessible Routes [§402] Components of accessible routes include walking surfaces, doorways, ramps, curb ramps, elevators, and, where permitted, platform lifts....
-
Maneuvering Space
At least one maneuvering space must be provided on the same level as elevated play components....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum.
-
1008.3.2.3 Transfer Supports
At least one means of support for transferring shall be provided. Advisory 1008.3.2.3 Transfer Supports. Transfer supports are required on transfer platforms and transfer steps to...
-
409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car.
-
409.4.7.4 Cord
The telephone cord shall be 29 inches (735 mm) long minimum.
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with 309.