(ii) Shopping center or shopping mall means –
Search Results "Elevator Bank"
Commonly Searched Documents
-
§ 36.401(d)(1)(ii)
-
Sec.36.401(d)(1)(ii)
(ii) Shopping center or shopping mall means --
-
409.4.4 Leveling
409.4.4 Leveling. Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions.
-
11B-411.2.1 Hall call consoles
Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3.
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4.
-
11B-407.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-407.4.8.2.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-411.2.1 Hall call consoles
Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309.
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4.
-
11B-407.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-407.4.8.2.
-
5f.
Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Stds 4.10.13]...
-
e-vii
Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Standards § 4.10.13] Yes No...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...