This stall is specifically designed for people who have difficulty walking or standing from a seated position....
Search Results "Assurances from Contractors"
-
36 Inch Wide Stalls
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524...
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
407.2 Contrast
Where provided, keys and controls shall contrast visually from background surfaces....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. ...
-
407.2 Contrast
Where provided, keys and controls shall contrast visually from background surfaces....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-502.4 Floor or ground surfaces
Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
-
11B-707.4 Privacy
Speech output users can benefit from an option to render the visible screen blank, thereby affording them greater personal security and privacy. ◼ ETA Editor's Note The Department...
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
104.11 Alternative materials, design and methods of construction and equipment
ETA Editor's Note Sections from the California Building Code Chapter 1 that are not adopted by the Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-707.4 Privacy
Speech output users can benefit from an option to render the visible screen blank, thereby affording them greater personal security and privacy. ◼ ETA Editor's Note The Department...
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
11B-502.4 Floor or ground surfaces
Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
-
ASTM: ADA Standard Section 105.2.3
Section 105.2.3 of the ADA Standards cover references to the American Society for Testing and Materials (ASTM) standards.
- District of Columbia Department on Disability Services (DDS): Vocational Rehabilitation (VR) Program
-
E202.2 National Security Systems (Section-by-Section Analysis)
Security Systems (Section-by-Section Analysis) This section proposes that ICT operated by agencies as part of a national security system, as defined by 40 U.S.C. 11103(a), is exempt from...
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
4.13.10* DOOR CLOSERS