EXHIBIT A Required Accessible Elements at QuikTrip Stores
-
4.3 Locker Room Barriers and Solutions
Restrooms are not large enough for a wheelchair user to maneuver Change hinges so door swings out, to provide more space Rearrange the restroom partitions to comply with ADAAG requirements...
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....
-
603.2.3 Door Swing
Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door....
-
603.2.3 Door Swing
Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor...
-
603.2.3 Door Swing
Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor...
-
Construction Sites: ADA Standard Section 203.2
Section 203.2 covers scoping requirements of general exceptions for construction sites in the most current ADA Standards.
-
Closers
Closers Automated door closing is addressed by the ANSI/BHMA standards....
-
D3. Door Hardware
Is the door hardware (e.g., lever, pull, panic bar) usable with one hand without tight grasping, pinching, or twisting of the wrist?...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
Turning Space: ADA Standard Section 805.2
Turning space complying with 304 shall be provided within the room....
-
Operating Hardware
Operating Hardware Common Problem: The shape of the hardware on accessible doors, and on faucets, fixed lamps, drapery controls, and heating and air conditioning controls in spaces...
-
11B-604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.2 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-612 Saunas and steam rooms
11B-612 Saunas and steam rooms....
- Bobrick Partition-Mounted Multi-Roll Toilet Tissue Dispenser (Serves 2 Compartments) B-386
- Gamco Partition Mounted Dual-Sided Multi-Roll Toilet Tissue Dispenser - TTD-7
- Norton Surface Mounted 5600 Hands-Free Door Operation Kits
- American Specialties Recessed Dual Roll Toilet Paper Holder 74022
-
11B-219.2 Required systems
An assistive listening system shall be provided in assembly areas, including conference and meeting rooms. [2010 ADA Standards] 219.2 Required Systems....