In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
Search Results "Single User Toilet Room"
Commonly Searched Documents
-
11B-206.5.3 Transient lodging facilities
-
Visible Alarms in Guest Rooms with Communication Features
Visible Alarms in Guest Rooms with Communication Features....
-
Turning Space: ADA Standard Section 806.2.6
Turning space complying with 304 shall be provided within the guest room....
-
Invisible Wounds: Emerging Promising Practices for Meeting Planners
In a concert or large presentation hall, hold seats along the sides of the room close to exits for individuals who may experience challenges with crowds....
- Access Board: Tactile Sign Location
- Access Board: Tactile Sign Height
-
Bobrick Partition-Mounted Multi-Roll Toilet Tissue Dispenser (Serves 2 Compartments) B-386
Requires the Premium User plan or above. (Login or upgrade your account!)
-
224 Transient Lodging Facilities and Guest Rooms
[See subsections ...]
-
11B-806.2.6 Turning space
Turning space complying with Section 11B-304 shall be provided within the guest room....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
Doorways
In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to be at least 32 inches wide (224.1.2)....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
Do reach range requirements apply to elements or only to operable parts of elements?
Reach range requirements apply to the operable portions of elements, including handles, controls, switches, buttons, control pads and other mechanisms that must be activated or...
-
Circulation Paths Serving Exempted Spaces [§203]
Circulation Paths Serving Exempted Spaces [§203] Portions of common use circulation paths serving exempt spaces within a work area are not required to comply, including...
-
5.3.6 Entrance
The entrance to the toilet shall be level with the surrounding surface....
-
B. Clear Width
Do bathroom doors in all guestrooms allow 32" clear passage width so persons who use wheelchairs, crutches, and other mobility aids can visit or stay in other rooms and use the bathroom?...
-
Facilities Specializing in Treating Conditions That Affect Mobility: ADA Standard Section 223.2.2
Section 223.2.2 covers scoping requirements in the current ADA Standards for facilities specializing in treating conditions that affect mobility.
-
11B-604.8.1.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
206.7.6 Guest Rooms and Residential Dwelling Units, F206.7.6 Guest Rooms and Residential Dwelling Units
206.7.6 Guest Rooms and Residential Dwelling Units F206.7.6 Guest Rooms and Residential Dwelling Units The final rule edits the references in these sections to the technical requirements...
-
H17
Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No...
-
5.3.5 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1.
-
Size and Arrangement [4.17.3]
[See subsections ...]