1132A.6 Closer-effort to operate doors. Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push...
Search Results "Residential Facility"
Commonly Searched Documents
-
1132A.6 Closer-effort to operate doors
-
1133A.1 General
1133A.1 General. Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.)
-
1132A.4.1, Item 2
2. Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal...
-
4.34.3 ADAPTABILITY
The specifications for 4.34.5 and 4.34.6 include the concept of adaptability. Accessible dwelling units may be designed for either permanent accessibility or adaptability.
-
4.34.2(9)
(9) All controls in accessible spaces shall comply with 4.27. Those portions of heating, ventilating, and air conditioning equipment requiring regular, periodic maintenance and...
-
A4.34.6.1 CLEARANCE
The minimum clearances provide satisfactory maneuvering spaces for wheelchairs only if cabinets are removed at the sink.
-
A4.34.6.6 RANGES AND COOKTOPS
Although not required for minimum accessibility, countertop range units in a counter with adjustable heights can be an added convenience for wheelchair users.
-
A4.34.6.8 REFRIGERATOR/FREEZERS
Side-by-side refrigerator/freezers provide the most usable freezer compartments. Locating refrigerators so that their doors can swing back 180 degrees is more convenient for...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in...
-
1132A.4 Level floor or landing
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors with changes in height between...
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.4.1, Item 2
2. Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm). Section 1126A.3...
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following:
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
11B-809.9 Kitchens
Kitchens shall be on an accessible route and shall comply with this section.
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm). Section 1126A.3...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in...
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following: A minimum linear length of 30 inches (762 mm) of countertop shall be provided for...
-
1132A.4 Level floor or landing
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors with changes in height between...
-
201.2.1 Commercial facilities and places of public accommodation located in private residences
201.2.1 Commercial facilities and places of public accommodation located in private residences....
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....