Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
Search Results "Maximum Extent Practicable"
-
11B-604.7 Dispensers and disposal units
-
11B-411.2.1.2.3 Accessibility function button
Each dot shall have a base diameter of 0.059 inch (1.5 mm) minimum and 0.063 inch (1.6 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
Q4.) Are conditions like door closers that require force in excess of the maximum allowed by the standards considered true tolerances or are they simply non-compliance with the maintenance requirements of 35.133 or 36.211?
A4.) In our opinion, the plain language of the term “Construction and Manufacturing Tolerances” does not include adjustable conditions that can meet the detailed requirements when...
-
§ 36.304(g)(2)
(2) To the extent that relevant standards for alterations are not provided in subpart D of this part, then the requirements of §36.304 shall not be interpreted to exceed the standards for...
-
4.1.6(2)
(2) Where a building or facility is vacated and it is totally altered, then it shall be altered to comply with 4.1.1 to 4.1.5 of 4.1, Minimum Requirements, except to the extent where it...
-
Sound Pressure Level: ADA Standard Section 706.4
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
Forward Approach: ADA Standard Section 704.2.1.2
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
Drinking Fountains for Standing Persons: ADA Standard Section 602.7
Section 602.7 covers the current ADA Standards for drinking fountains for standing persons.
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
405 Ramps
Often, it is not practicable that such ramps meet requirements for handrails, edge protection, running slope, and other specifications. Response....
-
12201(f) Fundamental alteration
—Nothing in this Act alters the provision of section 12182(b)(2)(A)(ii), specifying that reasonable modifications in policies, practices, or procedures shall be required, unless an entity...
-
105.1 General
The standards listed in 105.2 are incorporated by reference in this document and are part of the requirements to the prescribed extent of each such reference....
-
§ 36.302(e)(3)
(3) Guarantee that an accessible guest room reserved through the reservations service will be held for the reserving customer during the reservation period to the same extent that it guarantees...
-
Sec.36.304(g)(2)
(2) To the extent that relevant standards for alterations are not provided in subpart D of this part, then the requirements of Sec.36.304 shall not be interpreted to exceed the standards...
-
Sec.36.304(f) Selling or serving space
The rearrangement of temporary or movable structures, such as furniture, equipment, and display racks is not readily achievable to the extent that it results in a significant loss of selling...
-
§ 36.304(f) Selling or serving space
The rearrangement of temporary or movable structures, such as furniture, equipment, and display racks is not readily achievable to the extent that it results in a significant loss of selling...