Where provided in residential dwelling units required to comply with Section 11B-809.5, fire alarms shall comply with Chapter 9, Section 907.5.2.3.3 and carbon monoxide alarms shall...
Search Results "Audible Sign System"
-
11B-215.5 Residential facilities
-
205 Operable Parts
controls) shall comply with 4.27. 4.27.3 Exception: These requirements do not apply where the use of special equipment dictates otherwise or where electrical and communications systems...
- Figure 1003.3.1 (Exception 1) Clear Pier Space Reduction at Boat Slips – Drawing from the U.S. Access Board
- Figure 1003.3.1 Boat Slip Clearance – Drawing from the U.S. Access Board
- Figure 1003.3.1 (Exception 2) Edge Protection at Boat Slips – Drawing from the U.S. Access Board
-
Subtitle B: Public Transportation
vehicles, make good faith efforts to purchase or lease accessible used buses, remanufacture buses in an accessible manner, and, provide paratransit where they operate fixed-route bus or rail systems...
- Curbell Medical Specialty Call Cords
-
706.6 Peak Clipping Level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech. [ECTCR UFAS 4.33.7]
-
708.3 Handsets
Handset cords, if provided, shall be 29 inches (735 mm) long minimum.
-
§382.83 Through what mechanisms do carriers make seating accommodations?
[See subsections ...]
-
11B-706.6 Peak clipping level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
382.83 Through what mechanisms do carriers make seating accommodations?
382.83 Through what mechanisms do carriers make seating accommodations? ETA Editor's Note This section has no content in the original document.
-
11B-708.3 Handsets
Handset cords, if provided, shall be 29 inches (737 mm) long minimum.
-
Requirements to Remember for: Light Rail Projects
[See subsections ...]
-
Sec. 12143. Paratransit as a complement to fixed route service. [Section 223]
[See subsections ...]
-
4.28.3(3)
(3) The maximum pulse duration shall be two-tenths of one second (0.2 sec) with a maximum duty cycle of 40 percent. The pulse duration is defined as the time interval between initial...
-
Location and Spacing
Location and Spacing Rooms with an area than can be circumscribed by a circle 50 feet in radius can be covered by a single centrally located strobe of 75 cd. For very small rooms,...
-
4.28.3(5)
(5) The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz.
-
Mounting Height
Mounting Height ADAAG specifies a signal height 80 inches above the highest floor level within the space or 6 inches below the ceiling, whichever is lower. (This can be measured...
-
2.1.2.3 New York State Standards
2.1.2.3 New York State Standards Ambient electro-magnetic fields should not exceed 30 mA/meter; higher levels would preclude the installation of an IL in the particular location....
-
ADA Facility Compliance Survey & Report Options
ADA Facility Compliance Survey & Report Options Click here to view/download the pdf "ADA Facility Compliance Survey & Report Options" (20 KB) * * * * * * *
-
ADA+ Facilities Compliance Services
ADA+ Facilities Compliance Services Click here to view/download the pdf version (14 KB) "ADA+" includes Federal, State and Local Accessibility Standards and Access Regulations...
-
§ 37.43(f)(2)(vi)
(vi) When possible, other accessible elements (e.g., parking, storage, alarms).
-
11B-706.6 Peak clipping level
11B-706.6 Peak clipping level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.