- Zurn Model Z5560 Commercial EcoVantage ADA Height Elongated Toilet: Pressure-Assist Replacement Tank Kit Video
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
Wheelchair Transfer
Wheelchair Transfer The manner of approach and transfer to water closets varies among people with disabilities....
- Willoughby Industries ETW-1490-FM-HC Floor Mounted Blowout Series Water Closet
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor....
- Big John Toilet Support & Short Swivel Support informational video
- Big John Toilet Support & Short Swivel Support 7.5" to 14" Installation Video
- Big John Toilet Support & Short Swivel Support 5" to 7.5" Installation Video
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.
-
604.9.4 Grab Bars
Grab bars for water closets shall comply with 604.5....
-
604.9.4 Grab Bars
Grab bars for water closets shall comply with 604.5....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
604.9.4 Grab Bars
Grab bars for water closets shall comply with 604.5....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
Technical Memorandum TM 2013-17 Water Closet Clearance - Overlap
TM 2013-17 Water Closet Clearances - Overlap Effective Date: June 1, 2013 2012 TAS Reference: 604.3.2 Based on TAS 106.3 and the application of terms and definitions in...
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
- Caroma® USA Sydney Smart 305 Easy Height Elongated 1 Piece Toilet
- Mansfield Plumbing Flushing Systems Demonstration Video
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
- Sloan WETS 2050.1001-1.28 Manual HET Flushometer and HET Wall Hung Water Closet
-
d. i.
d. i. Provide an 18" distance between the side wall and the toilet centerline of the men's toilet room in the Banquet area. See Standards § 4.16.2.
- Sioux Chief Closet Flanges Demonstration Video