For cars with in-car lanterns, T shall be permitted to begin when the signal is visible from the point 60 inches (1524 mm) directly in front of the farthest hall call button and the audible...
Search Results "Visible Signal (Elevator Landing)"
-
11B-407.3.4 Door and signal timing
-
11B-407.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-407.4.8.1....
-
11B-407.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-407.4.8.1....
-
11B-407.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-407.4.8.1....
- Otis Gen2 Elevator
-
4.10.7* Door and Signal Timing for Hall Calls
For cars with in-car lanterns, T begins when the lantern is visible from the vicinity of hall call buttons and an audible signal is sounded....
-
4.10.7* DOOR AND SIGNAL TIMING FOR HALL CALLS
For cars with in-car lanterns, T begins when the lantern is visible from the vicinity of hall call buttons and an audible signal is sounded....
-
407.4.7.1.4 Visible Indicators
407.4.7.1.4 Visible Indicators. Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
Elevator Car Requirements: ADA Standard Section 407.4
Section 407.4 covers the current ADA Standards for elevator cars.
-
407.4.7.1.4 Visible Indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
407.4.7.1.4 Visible Indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
Door and Signal Timing for Hall Calls [4.10.7], Door Delay for Car Calls [4.10.8]
Timing, based on the distance between the farthest call button and the elevator door, begins with visible and audible signaling of car arrival....
-
11B-408.4.8 Emergency communications
Car emergency signaling devices complying with Section 11B-407.4.9 shall be provided....
-
11B-408.4.8 Emergency communications
Car emergency signaling devices complying with Section 11B-407.4.9 shall be provided....
-
A4.10.7 Door and Signal Timing for Hall Calls
This paragraph allows variation in the location of call buttons, advance time for warning signals, and the door-holding period used to meet the time requirement....
-
A4.10.7 DOOR AND SIGNAL TIMING FOR HALL CALLS
This paragraph allows variation in the location of call buttons, advance time for warning signals, and the door-holding period used to meet the time requirement....
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1....
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1....