No, compliance is not required on both sides of those doors or gates that can be used in one direction only. Compliance is required only on the usable side....
Search Results "Usable Door (FHA)"
Commonly Searched Documents
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-224.1.2 Guest room doors and doorways
Bathrooms doors shall be either sliding or hung to swing in the direction of egress from the bathroom. [2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways....
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
11B-605.5.3 Doors
Urinal compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
Section 1193.23 Product design, development and evaluation
Section 1193.23 Product design, development and evaluation This section requires that, where readily achievable, manufacturers must evaluate the accessibility, usability, and compatibility...
-
I. Staircase Replacements Are Alterations That Affect or Could Affect Usability
Replacing a staircase at a public transportation facility (A) is an alteration for purposes of the ADA and DOT’s implementing regulations and (B) affects or could affect the usability of...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
Swinging Doors and Gates: ADA Standard Section 404.2.4.1
Section 404.2.4.1 covers the current ADA Standards for maneuvering clearances at swinging doors and gates.
-
Recessed Doors and Gates: ADA Standard Section 404.2.4.3
Section 404.2.4.3 covers the current ADA Standards for maneuvering clearances at recessed doors and gates.
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
Revolving Doors, Gates, and Turnstiles: ADA Standard Section 404.2.1
Section 404.2.1 covers the current ADA Standards for revolving doors, gates, and turnstiles that are part of an accessible route.
-
Are exit doors usable only in one direction required to comply on both sides?
Under the ADA Standards, compliance is not required on both sides of those doors or gates that can be used in one direction only, such as exit-only doors....
-
Spring Hinges: ADA Standard Section 404.2.8.2
Section 404.2.8.2 covers the current ADA Standards for door and gate spring hinges.
-
28.1 Q. If an architect or builder chooses to follow the bathroom specifications in Requirement 7...are the other bathrooms in the dwelling unit required to have reinforced walls for grab bars?
The same would be true for other Requirements in the Guidelines, such as Requirement 5, which applies to usable light switches, electrical outlets, thermostats and other environmental controls...
-
11B-404.2.1 Revolving doors, gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
PHYSICAL PROVISIONS
PHYSICAL PROVISIONS Usable without simultaneous actions Provide at least one mode that does not require simultaneous actions....
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....