Wall mounted urinal with integral trap. ADA compliant. 3/4" top spud inlet and 2" I.P.S. outlet. High Efficiency, 0.5 Gpf. Outlet connection and mounting set....
Search Results "Urinal Rim Height"
Commonly Searched Documents
- TOTO® Commercial Washout High Efficiency Urinal, 0.5 GPF - ADA
- Willoughby Industries Ligature-Resistant Urinal ASUW-1314-HEU-BS with Washout Flush
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
11B-606.3 Height
11B-606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
Height: ADA Standard Section 1005.2.1
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface. EXCEPTION: Where a guard complying with sections...
- Willoughby Industries ASUW-1314-HEU-FA-BS Contoured High Efficiency Urinal with Washout Flush
-
Character Height: ADA Standard Section 703.5.5
Minimum character height shall comply with Table 703.5.5....
-
11B-804.3.2 Height
Exception: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-703.8.9 Height above floor
Heights of low resolution variable message sign characters shall comply with Table 11B-703.8.4, based on the size of the characters on the sign....
-
605.4 Flush Controls
605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.
-
605.4 Flush Controls
Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.
-
605.4 Flush Controls
Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.
-
Flush Controls [4.18.4]
Flush Controls [4.18.4] Flush controls must be mounted no more than 44 inches above the finished floor and must: be automatic or operable by one hand operate...
-
11B-411.4.11.1 Height
Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3.
- American Standard Jetbrook Urinal
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
-
R409.4 Height
R409.4 Height. Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....
- Neo-Metro Commercial Flush Valve for Urinals FV Urinal Series
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface.
-
903.5 Height
The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground.
-
903.5 Height
The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground.