Transfer step height shall be 8 inches (203 mm) maximum....
Search Results "Transfer Wall"
-
11B-1009.5.4 Transfer steps
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum....
-
11B-1009.5 Transfer systems
Transfer systems shall comply with Section 11B-1009.5....
-
11B-1009.5 Transfer systems
Transfer systems shall comply with Section 11B-1009.5....
-
Transfer Devices for Use with Amusement Rides: ADA Standard Section 1002.6
When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable....
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided....
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided....
-
11B-1008.3.1 Transfer platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with Section 11B-1008.3.1....
-
11B-1008.3.1 Transfer platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with Section 11B-1008.3.1....
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
Amusement Ride Seats Designed for Transfer: ADA Standard Section 1002.5
Amusement ride seats designed for transfer shall comply with 1002.5 when positioned for loading and unloading. Advisory 1002.5 Amusement Ride Seats Designed for Transfer....
-
11B-1008.3.2 Transfer steps
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
-
11B-1008.3.2 Transfer steps
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...