Required emergency warning systems shall activate a means of warning the hearing impaired....
Search Results "Tow-Away Warning Sign"
-
1009.12 Alarms/emergency warning systems/accessibility
-
106.5.24 Detectable Warning
A standardized surface feature built in or applied to walking surfaces or other elements to warn of hazards on a circulation path....
-
11B-216.13 Variable message signs
Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with Section 11B-703.8....
-
11B-216.13 Variable message signs
Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with Section 11B-703.8....
-
Dome Spacing: ADA Standard Section 705.1.2
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Dome Size: ADA Standard Section 705.1.1
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum...
-
11B-810.6 Rail station signs
Rail station signs shall comply with Section 11B-810.6. Exception....
-
11B-810.6 Rail station signs
Rail station signs shall comply with Section 11B-810.6. Exception....
-
11B-810.6 Rail station signs
Rail station signs shall comply with Section 11B-810.6....
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
Temporary Signs
Comments requested clarification on what constitutes a "temporary" sign. Response....
-
4.29.4 Detectable Warnings at Stairs
4.29.4 Detectable Warnings at Stairs. (Reserved)....
- SafetyStepTD Traditional Detectable Warning System
-
Detectable Warnings at Stairs [4.9.5]
A requirement for detectable warnings has not been specified because of lack of data regarding effectiveness....
- Armor-Tile Tactile Systems Cast In Place Detectable Warning Surface System
-
216 and 703 Signs
216 and 703 Signs The following types of signs, though they are not specifically subject to the 1991 Standards requirement for signs, will now be explicitly exempted by sections 216 and...
-
Sec.36.407 Temporary suspension of certain detectable warning requirements
Sec.36.407 Temporary suspension of certain detectable warning requirements....
-
Detectable Warnings
Rail platform requirements include specifications for detectable warnings along platform boarding edges not protected by screens or guards (810.5.2)....
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
407.2.3 Hoistway Signs
407.2.3 Hoistway Signs. Signs at elevator hoistways shall comply with 407.2.3....
-
Hoistway Signs: ADA Standard Section 408.2.3
Section 408.2.3: covers the current ADA Standards for limited-use/limited-application elevator hoistway signs.
-
810.5.2 Detectable Warnings
810.5.2 Detectable Warnings....