A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
Search Results "Telephone"
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
-
4.31.2 Clear Floor or Ground Space
A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
-
4.31.3* MOUNTING HEIGHT
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6....
-
4.31.3* Mounting Height
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6....
-
4.31.4 Protruding Objects
Telephones shall comply with 4.4....
-
4.31.4 PROTRUDING OBJECTS
Telephones shall comply with 4.4....
-
4.31.5(1)
(1) Telephones shall be hearing aid compatible....
-
4.31.5(2)
(2) Volume controls, capable of a minimum of 12 dbA and a maximum of 18 dbA above normal, shall be provided in accordance with 4.1.3. If an automatic reset is provided then 18 dbA...
-
4.31.6 CONTROLS
Telephones shall have pushbutton controls where service for such equipment is available....
-
4.31.6 Controls
Telephones shall have push button controls where service for such equipment is available....
-
4.31.8 CORD LENGTH
The cord from the telephone to the handset shall be at least 29 in (735 mm) long....
-
4.31.8 Cord Length
The cord from the telephone to the handset shall be at least 29 in (735 mm) long....
-
Telephones [4.31]
-
Scoping [4.1.3(17)(a) & (b)]
Scoping [4.1.3(17)(a) & (b)] ADAAG addresses public telephones (pay, closed circuit) that are fixed and requires access for people who use wheelchairs and for people who are deaf,...
-
Clear Floor or Ground Space [4.31.2], Mounting Height [4.31.3]
Clear Floor or Ground Space [4.31.2], Mounting Height [4.31.3] Generally, access can be provided with either a forward or side approach. Where multiple banks are provided on a...
-
Forward Approach
Forward Approach Clear floor space is required to the face of the unit; a portion can be provided below the unit where clearance is available for toes/knees. (Since the seated...
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space.
-
Hearing Aid Compatible and Volume Control Telephones [4.13.5] [sic]
Hearing Aid Compatible and Volume Control Telephones [4.13.5] [sic] ADAAG requires that wheelchair accessible public phones, including pay and closed circuit phones, provide a volume...
-
§35.161 Telecommunication Devices for the Deaf (TDD's)
communicate by the telephone alone....
-
Additions: ADA Standard Section 202.2
Section 202.2 covers the most current requirements for additions in existing building and facilities.
-
§35.162 Telephone Emergency Services
§35.162 Telephone Emergency Services Many public entities provide telephone emergency services by which individuals can seek immediate assistance from police, fire, ambulance, and other...
-
Telephones: ADA Standard Section 217
Section 217 covers scoping requirements in the current ADA Standards for telephones.
-
General: ADA Standard Section 217.1
Section 217.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for telephones.
-
Wheelchair Accessible Telephones: ADA Standard Section 217.2
Section 217.2 covers scoping requirements in the current ADA Standards for wheelchair accessible telephones.