Exception: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
Search Results "Structural Impracticability"
-
11B-1002.4.3 Gaps
-
106.5.62 Soft Contained Play Structure
A play structure made up of one or more play components where the user enters a fully enclosed play environment that utilizes pliable materials, such as plastic, netting, or fabric....
-
M305.2.2 Structural Strength
Transfer supports and their connections shall be capable of resisting vertical and horizontal forces of 250 pounds (1,112 N) applied at all points on the transfer support.
-
610.4 Structural Strength
stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting structure...
-
610.4 Structural Strength
stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting structure...
-
III-7.3120 Temporary structures
III−7.3120 Temporary structures (ADAAG §4.1.1(4)). Temporary buildings that are extensively used or are essential for public use are covered....
-
11B-610.4 Structural strength
11B-610.4 Structural strength....
-
Single Occupant Structures (§203.6)
Single Occupant Structures (§203.6) Single occupant structures accessed only by below-grade passageways or elevated above standard curb height Examples: toll booths that are accessed...
-
§104.23(c)(3)
(3) This section does not require recipients to make building alterations that have little likelihood of being accomplished without removing or altering a load-bearing structural member....
-
4.1.1(4) Temporary Structures
(4) Temporary Structures. These guidelines cover temporary buildings or facilities as well as permanent facilities....
-
11B-610.4 Structural strength
stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting structure...
-
11B-610.4 Structural strength
stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting structure...
-
5.4.11 Transfer Support Structural Strength for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.11 Transfer Support Structural Strength for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
- Structured Negotiation: A Winning Alternative to Lawsuits
-
1.9.1.2.1
1.9.1.2.1 Any building, structure, facility, complex or improved area, or portions thereof, which are used by the general public. Advisory 1.9.1.2.1....
-
1.9.1.2.1
1.9.1.2.1 Any building, structure, facility, complex or improved area, or portions thereof, which are used by the general public. Advisory 1.9.1.2.1....
-
201.3 Temporary and Permanent Structures
201.3 Temporary and Permanent Structures. These requirements shall apply to temporary and permanent buildings and facilities. Advisory 201.3 Temporary and Permanent Structures....
-
4.26.3 Structural Strength
The structural strength of grab bars, tub and shower seats, fasteners, and mounting devices shall meet the following specification:...
-
4.26.3 STRUCTURAL STRENGTH
The structural strength of grab bars, tub and shower seats, fasteners, and mounting devices shall meet the following specification: (1) Bending stress in a grab bar or seat induced by...
-
F201.3 Temporary and Permanent Structures
Advisory F201.3 Temporary and Permanent Structures....
-
201.3 Temporary and Permanent Structures
Advisory 201.3 Temporary and Permanent Structures....
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
11B-201.3 Temporary and permanent structures
[2010 ADAS] Advisory 201.3 Temporary and Permanent Structures. ...
-
11B-201.3 Temporary and permanent structures
[2010 ADAS] Advisory 201.3 Temporary and Permanent Structures. ...