An accessible route from the boundary of the site is not required where the only means of site arrival is a vehicular way without pedestrian access....
Search Results "Pedestrian Flow"
Commonly Searched Documents
-
If no pedestrian route onto a site is provided, is an accessible route still required?
-
Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way
Proposed Guidelines Developed Specifically for Pedestrian Facilities in the Public Right-of-Way The proposed guidelines are developed specifically for pedestrian facilities in the public...
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
Dispensers [4.16.6]
Dispensers must provide continuous paper flow; those that have separate sheets or that control delivery are prohibited because they require repetitive hand motion and pinching and are not...
-
11B-604.7.1 Dispensers
Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-604.7.1 Dispensers
Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
Drinking Fountain Water Flow Tool
Drinking Fountain Water Flow Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring drinking fountain water flow....
-
Issue 7: Repair/replacement (put it back right!)
Issue 7: Repair/replacement (put it back right!) An APS that was knocked down in a crash was reinstalled by workers who did not know how the device was supposed to function. After...
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
A red circle highlights where the pedestrian signal pole was supposed to be installed. ...
-
R302.5 Grade
Except as provided in R302.5.1, where pedestrian access routes are contained within a street or highway right-of-way, the grade of pedestrian access routes shall not exceed the general grade...
-
Chapter 6 Addendum: Title II Checklist (Curb Ramps and Pedestrian Crossings)
A list of the pedestrian crossings constructed by or on behalf of your entity since January 26, 1992....
-
Issue 6: Pre-timed signals (an APS is more than a pushbutton)
Issue 6: Pre-timed signals (an APS is more than a pushbutton) Since pedestrians don’t need to use the pushbutton to get a WALK signal at pre-timed signals or where pedestrian signals...
- Figure 604.7 Dispenser Outlet Location – Drawing from the U.S. Access Board
-
R302.6.1 Pedestrian Street Crossings Without Yield or Stop Control
R302.6.1 Pedestrian Street Crossings Without Yield or Stop Control....
-
Other Features
a light or beep), tactile crosswalk maps, and options activated by an extended button push: audible beaconing (useful for directional guidance at irregular or long crossings), extended pedestrian...
-
C. Why are Curb Ramps at Pedestrian Crossings Required?
It is often difficult or impossible for a person using a wheelchair, scooter, walker, or other mobility device to cross a street if the sidewalk on either side of the street ends...
-
WILLITS, et al v. CITY OF LOS ANGELES - Notice of Proposed Settlement of Class Action Lawsuit
have used, tried to use, or believe you will in the future use or try to use any of the City of Los Angeles’s sidewalks, intersections, crosswalks, streets, curbs, curb ramps, walkways, pedestrian...
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
R302.2 Components
Pedestrian access routes shall consist of one or more of the following components: 1....
-
Spout Location [4.15.3]
The trajectory of water flow must be vertically "parallel" or "nearly parallel" to the face of the unit....
-
R204.1 General
Pedestrian access routes shall be provided in accordance with R204 and shall comply with R302. Advisory R204.1 General....
-
R302.1 General
Pedestrian access routes shall comply with R302....
-
R217 Handrails
Where provided on pedestrian circulation paths, handrails shall comply with R409....