Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
Search Results "Finish"
-
11B-611.4 Height
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
11B-809.9.3 Removable base cabinets
permitted under sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish...
-
11B-809.9.3 Removable base cabinets
permitted under sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish...
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the finish...
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the finish...
-
Parallel Approach: ADA Standard Section 904.4.1
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
the kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish...
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
Spout Height: ADA Standard Section 602.4
Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....