Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
Search Results "Edge Protection"
-
Edge Protection: ADA Standard Section 1005.3
-
Curb or Barrier: ADA Standard Section 1005.3.1
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.
-
Extended Ground or Deck Surface: ADA Standard Section 1005.3.2
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided and shall be 30 inches (760 mm) wide minimum...
-
6g. Ramp Edge Protection
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Stds 4.8.7] Yes _____ No _____...
-
4g.
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Stds 4.8.7] Yes _____ No _____...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by...
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADAS] 405.9 Edge Protection. ...
-
11B-405.9.1 Reserved
11B-405.9.1 Reserved. [2010 ADAS] 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond...
-
11B-405.9.2 Curb or barrier
FIGURE 11B-405.9.2 ‡‡ CURB OR BARRIER EDGE PROTECTION ETA Editor's Note 2013 CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the...
-
11B-1003.3.1 Boat slip clearance
Each 10 feet (3048 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum. Exceptions: 1. ...
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum. Exceptions: 1. ...
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided and shall be 30 inches (762 mm) wide minimum...
- Boost Your Business - Chapter 4 - Ramps
- Figure 1003.3.1 (Exception 1) Clear Pier Space Reduction at Boat Slips – Drawing from the U.S. Access Board
- Figure 1003.3.1 (Exception 2) Edge Protection at Boat Slips – Drawing from the U.S. Access Board
- Figure 1003.3.1 Boat Slip Clearance – Drawing from the U.S. Access Board
- Figure 1003.3.2 (Exception 1) Clear Pier Space Reduction at Boarding Piers – Drawing from the U.S. Access Board
- Figure 1003.3.2 (Exception 2) Edge Protection at Boarding Piers – Drawing from the U.S. Access Board
- Figure 1003.3.2 Boarding Pier Clearance – Drawing from the U.S. Access Board
- Figure 1005.3.2 Extended Ground or Deck Surface at Fishing Piers and Platforms – Drawing from the U.S. Access Board
- Figure 405.9.1 Extended Floor or Ground Surface Edge Protection – Drawing from the U.S. Access Board
- Figure 405.9.2 Curb or Barrier Edge Protection – Drawing from the U.S. Access Board