Exceptions: Areas of refuge located within a stairway enclosure....
Search Results "Dumpster Enclosure"
Commonly Searched Documents
-
1007.6.2 Separation
-
704.5 TTY Shelf
Public pay telephones required to accommodate portable TTYs shall be equipped with a shelf and an electrical outlet within or adjacent to the telephone enclosure....
-
1134A.5 Bathtubs
Bathtub enclosures. Doors and panels of bathtub enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
1003.2.13.5.2 Separation
Areas of refuge located within a stairway enclosure. 2....
-
11B-704.5 TTY shelf
Public pay telephones required to accommodate portable TTYs shall be equipped with a shelf and an electrical outlet within or adjacent to the telephone enclosure....
-
1009.6.4 Separation
Exceptions: Areas of refuge located within an enclosure for interior exit stairways complying with Section 1023....
-
607 Bathtubs
Specifications for bathtubs in section 607 address clear floor space, seats, grab bars, operable parts, shower spray units, and enclosures....
-
1009.6.4 Separation
Areas of refuge located within an enclosure for interior exit stairways complying with Section 1023. 2....
-
4.3.11.1(7)
(7) An elevator lobby when elevator shafts and adjacent lobbies are pressurized as required for smokeproof enclosures by local regulations and when complying with requirements herein for...
-
Egress, Means of
A means of egress comprises vertical and horizontal travel and may include intervening room spaces, doorways, hallways, corridors, passageways, balconies, ramps, stairs, enclosures, lobbies...
-
C2-2. Undersides of Exterior Stairs
[ADA Stds 4.4.2] Yes _____ No _____ If No, can a barrier or enclosure be added below the stair or can the route be relocated away from the stair?...
-
Inclined Wheelchair Lifts
The ASME standard allows inclined lifts with enclosures and those without....
-
1134A.6 Showers
Shower enclosures. Doors and panels of shower enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged shower doors shall open outward....
-
1.1 Balance of System (BOS) Equipment
1.1 Balance of System (BOS) Equipment - The BOS equipment, along with the area or enclosure housing it, qualifies for the machinery space and path of travel exceptions as long as the installation...
-
Exposed Pipes and Surfaces [4.19.4]
If an under-lavatory enclosure is used, the specified knee and toe clearances must be maintained....
- Neo-Metro Commercial Wall Mounted Neo-Basin 8935 Series
-
11B-410.8 Restriction sign
A sign complying with Section 11B-703.5 shall be posted in a conspicuous place at each landing and within the platform, enclosure stating “No Freight” and include the International Symbol...
-
1013.4 Raised character and braille exit signs
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
1007.6 Areas of refuge
Where an elevator lobby is used as an area of refuge, the shaft and lobby shall comply with Section 1019.1.8 for smokeproof enclosures except where the elevators are in an area of refuge...
-
1003.2.13.5 Areas of refuge
Where an elevator lobby is used as an area of refuge, the shaft and lobby shall comply with Section 1005.3.2.5 for smokeproof enclosures except where the elevators are in an area of refuge...
-
5. Ground Level PV Systems
purposes of accessibility compliance, ground level PV systems fall into one of the two following types: 5A – Restricted Access: The PV system components are located within a secure enclosure...
-
1003.2.13.1 General
Stairways within exit enclosures complying with Sections 1003.2.13.2 and 1005.3.2. 3. Elevators complying with Section 1003.2.13.3. 4. Horizontal exits. 5. Smoke barriers....
-
Shelf and Outlet
The power outlet must be in or adjacent to the telephone enclosure (typical TTY cord is about 3 feet long)....
- Besam SW200i-IG In Ground Swing Door Operator