Signs required by Chapter 10, Section 1008.1.9.7, item 5.1 at doors with delayed egress locks shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters...
Search Results "Character Spacing (Raised)"
Commonly Searched Documents
-
11B-216.4.4 Delayed egress locks
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters...
-
11B-808.2 Turning space
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with Section 11B-304....
-
11B-203.10 Raised refereeing, judging, and scoring areas
Raised structures used solely for refereeing, judging, or scoring a sport shall not be required to comply with these requirements or to be on an accessible route....
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2....
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2....
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2....
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character....
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character....
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character. [ECTCR UFAS 4.30.4]...
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and braille. Raised characters shall be 2 inches (51 mm) high....
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high....
-
11B-407.4.9 Emergency communication
Raised symbols or characters, white on a black background, and Braille shall be provided adjacent to the device and shall comply with Sections 11B-703.2 and 11B-703.3....
-
11B-407.4.9 Emergency communication
Raised symbols or characters, white on a black background, and Braille shall be provided adjacent to the device and shall comply with Sections 11B-703.2 and 11B-703.3....
-
11B-407.4.9 Emergency communication
Raised symbols or characters, white on a black background, and Braille shall be provided adjacent to the device and shall comply with Sections 11B-703.2 and 11B-703.3....
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and braille. Raised characters shall be 2 inches (51 mm) high....
-
Characters
Letters, numbers, punctuation marks and typographic symbols.