11B-607.4.2.3 Head end wall. A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub....
Search Results "Back Wall"
-
11B-607.4.2.3 Head end wall
-
Clearance: ADA Standard Section 607.2
Section 607.2 covers the current ADA Standards for bathtub clearances.
-
M301.3.3 Head and Back Support
M301.3.3 Head and Back Support Proposed requirement: Where diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients...
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches long minimum shall be installed on the head end wall at the front edge of the bathtub....
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
Effect of Handhelds on Transfer Height
For protocol C the medium and short back rests were almost equally preferred....
-
Width and Length
Width and Length Transfer walls must be a minimum of 12 inches wide to a maximum of 16 inches wide....
-
Grab Bar and Backrest Evaluation
Grab bar and backrest preferences were reported in this study with the tall grab bar and the short backrest being selected more often than the short grab bars and medium and tall...
-
Closers
In addition, ADAAG requires that low-energy doors not open to back check faster than 3 seconds and require no more than 15 Ib, which is consistent with ANSI/BHMA A156.19....
-
Gates and Barriers on Trails
If gates or barriers are constructed to control access to trails, include openings wide enough to allow hiker passage. Refer to the FSTAG for the technical provisions for gates and...
-
7.4.12 Gates and Barriers
Where gates or barriers are constructed to control access to trails, gates and barriers shall comply with 7.4.12.
- Figure 1009.4.5 Grab Bars for Transfer Walls – Drawing from the U.S. Access Board
- Figure 1009.4.1 Clear Deck Space at Transfer Walls – Drawing from the U.S. Access Board
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-1009.4.5 Grab bars