Hot water and drain pipes exposed under sinks shall be insulated or otherwise configured so as to protect against contact. There shall be no sharp or abrasive surfaces under sinks....
Search Results "Water Supply"
-
4.24.6 Exposed Pipes and Surfaces
-
4.34.6.5(8)
Hot water and drain pipes under sinks shall be insulated or otherwise covered. Figure 51 Kitchen Sink...
-
Wet Conditions [§405.10]
Wet Conditions [§405.10] Landings subject to wet conditions must be designed to prevent the accumulation of water....
-
Soiltac Liquid Topical
Soiltac Liquid Topical is mixed with water and sprayed onto 4 inches of ¼ inch minus compacted limestone aggregate. The stabilizer has a penetration depth of 1/8 inch....
-
J4
Does the water rise at least 4 inches high when no more than 5 pounds of force is applied to the controls of the fountain? [ADA Standards §§ 4.15.3 and 4.15.4] Yes No...
-
68.10(12) Element
., telephone, curb ramp, door, drinking fountain, seating, water closet, or public right-of-way....
-
Clear Deck Space
This space must be located on the side of the seat opposite the water. The slope of the clear deck space must not be greater than 1:48 (2%)....
-
213.3.1 Toilet Compartments
compartment required to comply with 604.8.1, at least one compartment shall comply with 604.8.2 where six or more toilet compartments are provided, or where the combination of urinals and water...
- Aqua Creek Pro Pool Lift
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
Submerged Depth
Submerged Depth Lifts must be designed so that the seat will submerge to a minimum of 18 inches below the stationary water level....
-
4.15.2* SPOUT HEIGHT
Figure 27 Drinking Fountains and Water Coolers...
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
Trail Study Sites
Layout of the path across the beach was sloped so that the edge of the path would not hold water....
-
11B-604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
205 Operable Parts, F205 Operable Parts
Exception 11 (Water Shut-Off Valves) The final rule adds Exception 11 for water shut-off valves....
-
G.6.iv. - What should be included in the undue burden determination?
meets the applicable technical provisions along with an explanation of how costs were estimated, and a description of all the funds available to the program or component for which the supply...
-
C201.2 Readily Achievable
the action needed to provide accessibility or compatibility; the overall resources of the telecommunications manufacturer, including financial resources, technical expertise, component supply...
-
7. Seating Accommodations
Therefore, this rule does not mandate that carriers allow users of respiratory assistive devices to plug their devices into the aircraft’s power supply or to provide priority seating near...
-
§35.190(b)(5)
(5) Department of Interior: all programs, services, and regulatory activities relating to lands and natural resources, including parks and recreation, water and waste management, environmental...
-
§ 35.190(b)(5) Department of Interior
(5) Department of Interior: All programs, services, and regulatory activities relating to lands and natural resources, including parks and recreation, water and waste management, environmental...
- Envirobond is Self-Healing