If the United States believes that this Agreement or any portion of it has been violated, it will raise its concerns with AJM Law and the parties will attempt to resolve the concerns in...
Search Results "Uppercase Character (Raised)"
Commonly Searched Documents
-
OTHER PROVISIONS
- Spectrum Aquatics Bozeman Therapy Steps
- Mighty 600 Pool & Spa Access Lift
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
-
5.3.6 Entrance
Exception: Where bedrock, perma-frost or other environmental conditions prohibit a level entry or the toilet design (such as a composting toilet) necessitates a raised toilet structure,...
-
Controls
Recommendations: Buttons and plates should be raised or flush and at least ¾ inch in diameter (as specified for elevator control panels)....
-
5.3.6 Entrance
Exception: Where bedrock, perma-frost or other environmental conditions prohibit a level entry or the toilet design (such as a composting toilet) necessitates a raised toilet structure,...
-
§ 38.95(b)(3) Emergency operation
The lift shall incorporate an emergency method of deploying, lowering to ground or platform level with a lift occupant, and raising and stowing the empty lift if the power to the lift fails...
-
§ 38.125(b)(3) Emergency operation
The lift shall incorporate an emergency method of deploying, lowering to ground or station platform level with a lift occupant, and raising and stowing the empty lift if the power to the...
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
-
11B-411.2.1.2.5 Audio output
shall provide verbal announcements of operating instructions, location and use of the star (*) and minus sign (-) buttons, user input confirmation, announcement of the elevator assignment characters...
-
F216.13 Trailhead Signs
Tactile characters are not required on exterior signs. Trail information signs are not required to display the International Symbol of Accessibility....
-
1009.11 Instructions
Signage shall comply with Chapter 11A, Section 1143A or Chapter 11B, Section 11B-703.5 requirements for visual characters. The instructions shall include all of the following: 1....
- Rebuilding Together Seattle - Seattle, WA
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
Adjustable height protocol
The amount of vertical distance that the seat was raised/lowered each time depended on the subject’s perceived and observed transfer abilities....
-
Section 2. Slope
For example, if a principal entrance is ten feet from a passenger loading zone, and the principal entrance is raised one foot higher than the passenger loading zone, then the slope is 1/...
-
4.29.2* Detectable Warnings on Walking Surfaces
Detectable warnings shall consist of raised truncated domes with a diameter of nominal 0.9 in (23 mm), a height of nominal 0.2 in (5 mm) and a center-to-center spacing of nominal 2.35 in...
-
Is there a minimum distance between changes in level?
Such level changes may need to be in close proximity, such as at raised thresholds (otherwise a minimum 48” separation will provide enough wheelchair space so that only one vertical change...
-
Are all public use and common use areas required to be accessible?
., certain types of limited use or raised spaces) or that are covered by provisions that require only a specified portion to comply (e.g., transient lodging guest rooms and patient bedrooms...
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...