Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
Search Results "United States Supreme Court"
Commonly Searched Documents
-
11B-809.10.8.1 Location
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than...
- California Department of Fair Employment and Housing
-
Detention/Correctional and Residential Facilities (§203.7 and §203.8)
Correctional and Residential Facilities (§203.7 and §203.8) Common use spaces in detention/ correctional facilities or residential facilities that do not serve accessible cells or dwelling units...
-
7.0 APPLICATION
As stated in the Federal Register, these guidelines would be updated periodically to ensure they remain equal to or a higher standard than other guidelines and standards applicable to Federal...
-
Alterations Affecting Primary Function Areas—Exception to Section 202.4 of the 2010 Standards
Under the Exception to Section 202.4, residential dwelling units are exempted from this requirement....
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
[F] 907.5.2.3.4 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
233.3.4.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
[F] 907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
-
THE UNITED STATES' INVESTIGATION AND FINDINGS
On May 15, 2015, the United States notified the Supervisor by letter that it had opened a compliance review in response to a complaint filed with the Department alleging that the Supervisor...
-
11B-606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...
-
11B-606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...
-
11B-606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...
-
First Occupancy
The Act states that covered multifamily dwellings subject to the Act's accessibility requirements are those that are "for first occupancy" after March 13, 1991....
-
233.3.4.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
§ 36.605 Procedure following preliminary denial of certification.
[See subsections ...]
-
Sec.36.606 Procedure following preliminary denial of certification
Sec.36.606 Procedure following preliminary denial of certification.
-
Required for Public Entities with Fifty or more Employees
[See subsections ...]
-
III-9.6000 Procedure following preliminary denial of certification
III−9.6000 Procedure following preliminary denial of certification. If the preliminary determination is to deny certification, then there will be no hearing. The Department will...
-
1(1)(b) Multiple entrances
Only one entrance is required to be accessible to any one ground floor of a building, except in cases where an individual dwelling unit has a separate exterior entrance, or where the building...
-
§ 36.406(d) Social service center establishments.
Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping accommodations or residential dwelling units that are subject...
-
11B-809.10.2 Number of complying bathing rooms and fixtures
One bathing room and one fixture of each type within the dwelling unit shall be designed to comply with the following: Maneuvering space in toilet, bathing and shower rooms shall...