1007.2 Continuity and components. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
Search Results "Ramp"
Commonly Searched Documents
-
1007.2 Continuity and components
-
1009.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
-
Basic Components for Accessible and Usable Public and Common Use Areas or Facilities
[See subsections ...]
-
§27.75 Federal Highway Administration—highways.
[44 FR 31468, May 31, 1979, as amended by Amdt. 27-3, 51 FR 19017, May 23, 1986. Redesignated at 56 FR 45621, Sept. 6, 1991, as amended at 79 FR 21405, Apr. 16, 2014]
-
B5. Curb Ramp
Is a curb ramp provided between the vehicle pull up area and the access aisle (see figure above) or the access aisle and the accessible route (see figure on page 9) to the accessible entrance...
-
Priority 2: Access to Goods & Services
Word Fillable Form (2.5MB) Word Non-Fillable Form (2.4MB) PDF Non-Fillable Form (1.4MB)
- The Corada Shop
-
§27.75(a) New facilities.
(a) New facilities—
-
4.7.5 SIDES OF CURB RAMPS
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, then it shall have flared sides; the maximum slope of the...
-
Guidelines for Requirement 2
For example, a ground floor entry might have three steps up to an elevator lobby, with a ramp located besides the steps....
-
R407.9.1 Extended Ramp Surface
R407.9.1 Extended Ramp Surface. The surface of the ramp run or landing shall extend 305 mm (1.0 ft) minimum beyond the inside face of a handrail complying with R409....
-
406.3 Sides of Curb Ramps
406.3 Sides of Curb Ramps. Where provided, curb ramp flares shall not be steeper than 1:10. Figure 406.3 Sides of Curb Ramps...
-
4.7.5 Sides of Curb Ramps
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, it shall have flared sides; the maximum slope of the flare...
-
Interior Routes
11B-302.2 Vertical clearances/protrusions along circulation paths. 11B-307 Running and cross slopes at walking surfaces and ramps...
-
Interior Routes
11B-302.2 Vertical clearances/protrusions along circulation paths. 11B-307 Running and cross slopes at walking surfaces and ramps...
-
Sides of Curb Ramps [4.7.5]
Where pedestrians cross the ramp, curb ramps are required to have side flares; sharp returns present tripping hazards....
- Regional Access & Mobilization Project (RAMP) - Rockford, Belvidere, DeKalb, Freeport, IL
-
Section C: Exterior Route
(§307.4) C8 If the route crosses a curb, is there a curb ramp that is at least 36" wide with a slope no more than 1:12?...
-
406.3 Sides of Curb Ramps
Where provided, curb ramp flares shall not be steeper than 1:10. Figure 406.3 Sides of Curb Ramps...
-
6g. Ramp Edge Protection
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Stds 4.8.7] Yes _____ No _____...
-
Miniature Golf Facilities
Word Fillable Form (1.0MB) Word Non-Fillable Form (1.0MB) PDF Non-Fillable Form (0.5MB)
-
11B-250 Circulation paths
[See subsections ...]
-
Re: When is a Curb Ramp a Ramp?
Curb height say 6'' The lowest slope for a ramp would be 5.1% or just under 1:20 So if the walkway was shorter than 10' I think it could be called a curb ramp and would only require...
-
Section A: Parking
(Note: Curb ramps may not be part of an access aisle since they include slopes greater than 1:48.) (§502.4) A5 Are the surfaces of the designated...