Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
Search Results "Push Side"
Commonly Searched Documents
-
608.5.3 Alternate Roll-In Type Shower Compartments
-
11B-608.2.2.1 Clearance
[2010 ADAS] EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
11B-608.2.2.1 Clearance
[2010 ADA Standards] EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the...
-
Spy City Café
The force required to push or pull open the interior hinged vestibule doors to the men's and women's toilet rooms designated as accessible is 10 pounds of force (lbf), which exceeds the...
-
Off-Road Racing Wheelchairs
If used, gearing is accomplished through multiple push rims. A long and wide wheelbase with camber on the rear wheels is used to increase stability on a variety of terrains....
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
1013.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
T213.3 Armrests at Aisle Seats on Over-the-Road Buses
Where armrests are provided on the aisle side of seats on over-the-road buses, folding or removable armrests shall be provided on the aisle side of at least 50 percent of aisle seats....
-
11. Door Maneuvering Clearance
Is there adequate room for a person who uses a wheelchair to approach the bathroom door in each accessible guestroom bathroom from the pull side and pull it open without it hitting the wheelchair...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
- Pilot Rock CN-OKR Oak Knoll Collection Trash Receptacle
- Corbin Russwin Inc. DC62900 Series Electromechanical Closer-Holder
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
404.2.4.2 Doorways without Doors or Gates
Doors, and Manual Folding Doors Minimum Maneuvering Clearance Approach Direction Perpendicular to Doorway Parallel to Doorway (beyond stop/latch side...
-
Recessed Lavatories
Recessed Lavatories Recessing lavatories can provide space for side transfers while allowing a narrower room width....
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
The proposed provision requires standing supports be provided on each side of the standing surface....
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
The Committee recommends measuring the transfer surface from the center-point of each side of the transfer surface....