Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7. Base cabinets (including...
Search Results "Multifamily Dwelling (HUD 504)"
-
1133A.3 Removable base cabinets
-
1131A.1 Changes in level not exceeding ½ inch
Abrupt changes in level along any accessible route shall not exceed ½ inch (12.7 mm). When changes in level do occur, they shall be beveled with a slope no greater than 1 unit...
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
11B-708.4.1 Common use or public use system interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
11B-708.4.1 Common use or public use system interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
11B-809.8 Doors
DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Language addressing interior doors within residential dwelling...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
202.3 Alterations
Residential dwelling units not required to be accessible in compliance with a standard issued pursuant to the Americans with Disabilities Act or Section 504 of the Rehabilitation Act of...
-
Standards Applicable Prior to March 15, 2012
Because under Education's Section 504 regulations we apply the same accessibility standards for new construction and alterations to private and public recipients, this notice applies to...
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
A. Yes. The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet.
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
A. No. The requirements in the Guidelines must be included at the time of construction. Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that...
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door...
-
7(1)(b)
(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches.