Toe clearance shall be provided and shall be 30 inches (762 mm) wide minimum and 9 inches (229 mm) minimum above the ground or deck surface beyond the railing....
Search Results "Handrail Clearance"
-
11B-1005.3.2 Extended ground or deck surface
-
1005.3.2 Extended Ground or Deck Surface
Toe clearance shall be provided and shall be 30 inches (760 mm) wide minimum and 9 inches (230 mm) minimum above the ground or deck surface beyond the railing....
-
1008.2 Accessible Routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches high (2030 mm) minimum....
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
-
11B-1008.2 Accessible routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches (2032 mm) high minimum....
-
11B-1008.2 Accessible routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches (2032 mm) high minimum....
-
11B-1008.2 Accessible routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches (2032 mm) high minimum....
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
This commenter asserted that the proposed six-inch vertical clearance would require redesign of every medical bed and stretcher on the market, and recommended reducing the required clearance...
-
Elevator Car Requirements [§407.4.2 – §407.4.5]
Elevator Car Requirements [§407.4.2 – §407.4.5] Other requirements for elevator cars include: compliant floor surfaces a maximum 1¼” horizontal clearance between car...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1005.3.2 Extended Ground or Deck Surface
Toe clearance shall be provided and shall be 30 inches (760 mm) wide minimum and 9 inches (230 mm) minimum above the ground or deck surface beyond the railing....
-
11B-1005.3.2 Extended ground or deck surface
Toe clearance shall be provided and shall be 30 inches (762 mm) wide minimum and 9 inches (229 mm) minimum above the ground or deck surface beyond the railing....
-
1005.3.2 Extended Ground or Deck Surface
Toe clearance shall be provided and shall be 30 inches (760 mm) wide minimum and 9 inches (230 mm) minimum above the ground or deck surface beyond the railing....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided....
-
Appendix 2- Photos of Participants in the IDEA Center Research
Clear Floor Area Lengths: Examples of People with Very Limited Reaching Ability: Examples of People with High Lap Heights: Examples of People Requiring Deep Knee Clearances...
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
1134A.8, Item 4.2
4.2. Any cabinet beneath the lavatory shall be removable without the use of specialized knowledge or specialized tools; or,
-
1133A.2, Item 1
1. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop.
-
§ 35.151(e)(1)
(1) In sleeping rooms covered by this section with more than twenty-five beds, five percent (5%) minimum of the beds shall have clear floor space complying with section 806.2.3.
-
1134A.8, Item 4.1
4.1. The space beneath the lavatory shall be left clear and unobstructed;
-
6.3(3)
(3) Each bedroom shall have adequate space to provide a minimum clear floor space of 36 in (915 mm) along each side of the bed and to provide an accessible route complying with 4.3.3...