This requirement is intended to affect decisions about where to locate entrances, boarding locations (e.g., where a mini-high platform is used for boarding), and other key elements of a...
Search Results "Entrance"
-
Section 206.3
-
§ 38.159(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches (1220 mm)....
-
[ADA Title II §35.151(b)(4)(i)] Primary function
(A) Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function....
-
Text Telephones (TTY)
provided at a bank of pay telephones and where at least one public pay telephone is provided on a floor or in a public building, where at least one public pay telephone serves a particular entrance...
-
When do path of travel and/or accessible routes apply? …new construction? …alterations to a parking area? …alterations to a building associated with parking, such as expansion or remodel?
RESPONSE: In each case EVCS required to be accessible must have an accessible route to the facility entrance (see CBC Section 11B-812.5.1) and an accessible route from the vehicle space...
- Cal-Royal CR6000 Series Digital Touch Screen Door Lock
- Balco FMS-A and FMS-V Roll-Up Floor Mat
- Lift-U® LU12 Step/Platform Onboard Lift
-
1134A.6 Showers
The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or 1.2. ...
-
[ADA Titles II & III] Primary Function
Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors, _|ADA Title III: and restrooms|_ are not areas containing...
-
Accessible Routes to Press Boxes
An accessible route is not required to press boxes with 500 square feet or less of aggregate space that are located on bleachers with entrances on only one level (Exception 1)....
-
1133B.2.5.1
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.2 Doors. 1133B.2.5.1 Door closer. ...
-
R204.2 Pedestrian Circulation Paths
this document and to accessible routes required by section 206.2.1 of appendix B to 36 CFR part 1191 or section F206.2.1 of appendix C to 36 CFR 1191 that connect building and facility entrances...
-
106.5.25 Disproportionality
Costs that may be counted as expenditures required to provide an accessible path of travel may include: (i) Costs associated with providing an accessible entrance and an accessible route...
-
Are carriers required to provide wheelchair service from the curb to the airplane or only from the ticket counter to the airplane?
I need wheelchair assistance getting from the curb, at the entrance to the airport, to the airplane....
-
G. Other types of equipment and furniture
equipment and furniture exists that may provide ready access for individuals with disabilities, including pool chairs that permit individuals who use wheelchairs to enter a pool with a sloped entrance...
-
Location and Signage
Signs are required at all phone banks without TTYs indicating the location of the nearest TTY; (if there are no other banks, directional signage is required at building entrances....
-
4.1.2(5)(a)
They may be provided in a different location if equivalent or greater accessibility, in terms of distance from an accessible entrance, cost and convenience is ensured....
-
Portable tactile maps
Some guides suggest the use of “no more than three distinct line types, three different textures and four or five point symbols, such as stairs and building entrances (Rowell and Ungar,...
-
Technical difficulty and readily achievable
A business with several front entrance steps that is close to a city street may not be able to provide an exterior ramp....
-
Employee Work Areas [§206.2.8]
This requires a connecting accessible route to the work area, a compliant entrance, including entry doors or gates, and a wheelchair space within the work area....
-
11B-216.9.2 Directional signs
If a facility has no banks of telephones, the directional signs shall be provided at the entrance or in a building directory....
-
[ADA Titles II & III] Primary Function
Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors, _|ADA Title III: and restrooms|_ are not areas containing...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...