Exception 1 to Section 206.2.3 of the 2010 Standards contains an elevator exception for private buildings or facilities that are less than three stories or that have less than 3,000 square...
Search Results "Elevator Keypad"
Commonly Searched Documents
-
Elevator Exception 1—Section 206.2.3 of the 2010 Standards
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
§ 36.304(b)(6)
(6) Adding raised markings on elevator control buttons;...
-
Sec.36.304(b)(6)
(6) Adding raised markings on elevator control buttons;...
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1....
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1....
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1....
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
11B-407.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-407.4.8.2.
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3.
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4.
-
11B-411.2.1 Hall call consoles
Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
-
409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions.
-
407.4.3 Platform to Hoistway Clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
-
407.4.8.2 Audible Indicators
Audible indicators shall comply with 407.4.8.2.
-
10. Can a transfer platform be an irregular shape as long as it incorporates the minimum rectangle of 14 by 24 inches?
10. Can a transfer platform be an irregular shape as long as it incorporates the minimum rectangle of 14 by 24 inches? Yes. While permitted, providing odd shaped or textured...
-
407.4.3 Platform to Hoistway Clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1 1/4 inch (32 mm) maximum.
-
407.4.8.2 Audible Indicators
Audible indicators shall comply with 407.4.8.2.
-
409.4.4 Leveling
Each car shall automatically stop at a floor landing within a of 1/2 inch (13 mm) under rated loading to zero loading conditions.
-
e-i
e-i. Are the centerlines of the call buttons mounted 42 inches above the floor? [ADA Standards § 4.10.3] Yes No