In the proposed rule, an exception to this provision noted that a portion of this space (6 inches maximum) could extend under partitions or openings without doors that provide toe clearance...
Search Results "Door Pull"
-
803 Dressing, Fitting, and Locker Rooms
- Panda S.10 All Aluminum Lift & Slide - Pocket Door System
- S.74 Aluminum Wood Clad Folding Door System Corner Detail
- Panda S.65 Aluminum Wood Clad Multi Slide Door System
- Panda S.65 Aluminum with Aluminum Clad Multi Slide Door System
- Panda TS.60 Thermally Broken Folding Door System Video 2
- Panda TS.60 Thermally Broken Folding Door System Video 1
- Panda S.10 All Aluminum Lift & Slide - Stackable Door System
-
11B-207.1 General
Doors that provide access only to interior or exterior stairways shall not be required to comply with Section 11B-404....
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008....
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008....
-
Building Entrance
At least one door at the accessible entrance must have a minimum clear width of 32 inches for a voter who uses a wheelchair or other mobility device to pass through the doorway....
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-603.2.3 Door swing
11B-603.2.3 Door swing. Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-603.2.3 Door swing
Other than the door to the accessible water closet compartment, a door in any position, may encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-603.2.3 Door swing
[2010 ADA Standards] 603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture....
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008....
- Panda S.81 All Aluminum Multi-Slide Door System Corner Detail
- Panda S.11 Lift & Slide Wood Clad Radius Pocket Door System
- Panda TS.83 Thermally Broken Multi-Slide Door System Corner Detail
- Panda S.90 All Aluminum Slim Profile Multi-Slide Door System
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger drop-off andĀ loading zone and from the passengerĀ drop-off and loading zone to...
-
T503.3 Steps at Front Doorways
The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
-