around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
Search Results "Space Allowance"
Commonly Searched Documents
-
11B-604.3.2 Overlap
-
11B-1002.4.4 Clearances
Clearances for wheelchair spaces shall comply with Section 11B-1002.4.4. Exceptions: 1. ...
-
221.2.1.1 General Seating
Wheelchair spaces complying with 802.1 shall be provided in accordance with Table 221.2.1.1. Table 221.2.1....
-
11B-1002.4.4 Clearances
Clearances for wheelchair spaces shall comply with Section 11B-1002.4.4. Exceptions: 1....
-
Ticket transfer. (Section-by-Section Analysis)
The proposed regulation at § 36.302(f)(5) required that individuals with disabilities must be allowed to purchase season tickets for accessible seating on the same terms and conditions as...
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
221.2.1.1 General Seating
Wheelchair spaces complying with 802.1 shall be provided in accordance with Table 221.2.1.1....
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
Wheelchair seating locations must provide lines of sight comparable to those provided to other spectators.
A comparable line of sight, as illustrated in the figure below, allows a person using a wheelchair to see the playing surface between the heads and over the shoulders of the persons standing...
-
F221.2.1.1 General Seating
Wheelchair spaces complying with 802.1 shall be provided in accordance with Table F221.2.1.1....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
§ 38.83(a)(1) General
complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas, each with a minimum clear floor space...
-
5.8.1 Wheelchair Spaces on Raised Platforms
5.8.1 Wheelchair Spaces on Raised Platforms....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
Section 35.151(g)(3)
Further, use of temporary platforms allows facilities to limit persons who need accessible seating to certain seating areas, and to relegate accessible seating to less desirable locations...
-
1134A.8, Item 2
Floor space. A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
-
1134A.8, Item 2
Floor space. A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching...
-
4.4.5 Slope
The slope of the clear floor or ground space for benches shall not exceed 1:48 (2 percent) in any direction. Exception....
-
We are also being asked to show the future space for the 1 Van accessible EV space that would be required in the future, if the equipment was installed. And due to the requirement for the access aisle beside this space, in the future it would be converted to an access aisle resulting in the loss of one parking space. As this project is right at the required number of parking spaces per zoning, it is not acceptable to the zoning reviewer to sign off on a plan that shows a “future access aisle for future EV van accessible charging space,” as they are approving the loss of a parking space, even though this would not happen until a future condition, upon which I assume there would be some review process for installation of EV charging equipment. What is the appropriate path forward in this situation?
RESPONSE: All work is required to comply with the applicable codes, standards and ordinances. Parking ordinances are typically adopted within each city and county in California....