In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
Search Results "Shower Room"
-
11B-224.8.1 More than 25-bed sleeping rooms
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
-
11B-805 Medical care and long-term care facilities
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610. ...
-
907.2.6.2.3 Smoke detectors
An approved automatic smoke detection system shall be installed throughout resident housing areas, including sleeping areas and contiguous day rooms, group activity spaces and other common...
-
(5) Reinforced walls for grab bars
The only change made to these guidelines has been to subject powder rooms to the reinforced wall requirement when the powder room is the only toilet facility on the accessible floor of a...
- Symmons Hand Shower T-600B-36-V
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates.
-
Accessible Information Exchange: Meeting on a Level Playing Field
U.S. Department of Justice Civil Rights Division Disability Rights Section Accessible Information Exchange: Meeting on a Level Playing Field
-
Feature 4 - Temporary Barrier Removal for Routes to the Meeting Space
Feature 4 - Temporary Barrier Removal for Routes to the Meeting Space
-
Feature 2 - Temporary Barrier Removal for Routes to the Building Entrance
Feature 2 - Temporary Barrier Removal for Routes to the Building Entrance
-
Auxiliary Aids and Services
Auxiliary Aids and Services: If auxiliary aids and services are requested by guests, meeting organizers will need to address before the meeting takes place how to provide such...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground. Mirrors shall be full length with a reflective...
-
11B-805.2.1 Hand washing fixtures
Hand washing fixtures shall comply with Section 11B-606.
-
11B-805.2.1 Hand washing fixtures
Hand washing fixtures shall comply with Section 11B-606.
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground. Mirrors shall be full length with a reflective...
-
11B-805.2.1 Hand washing fixtures
Hand washing fixtures shall comply with Section 11B-606.
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground. Mirrors shall be full length with a reflective...
- SafePath SafeShower™ Ramp Transitions
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
- Curbell Medical Specialty Call Cords
-
Door Maneuvering Clearance
The proposed rule exempted doors to hospital patient rooms that are at least 44 inches wide from the specifications for latch side clearances....
- Figure 608.2.2 Standard Roll-In Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
-
11B-223.2.1 Facilities not specializing in treating conditions that affect mobility
conditions that affect mobility, including hospitals, psychiatric and detoxification facilities, at least 10 percent, but no fewer than one, of the patient bedrooms or resident sleeping rooms...