At least one bathroom shall comply with Section 11B-603. No fewer than one of each type of fixture provided within the bathroom shall comply with applicable requirements of Sections...
Search Results "Head Room"
-
11B-809.4 Toilet facilities and bathing facilities
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section.
-
11B-809.4 Toilet facilities and bathing facilities
At least one bathroom shall comply with Section 11B-603. No fewer than one of each type of fixture provided within the bathroom shall comply with applicable requirements of Sections...
-
1134A.2 Number of complying bathrooms
Bathrooms shall be designed to comply with one of the following options: Option 1. All bathrooms within the dwelling unit shall be designed to comply with the...
-
SECTION 1134A BATHING AND TOILET FACILITIES
[See subsections ...]
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section.
-
11B-802.2.1.2 Lines of sight between heads
Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces...
-
11B-802.2.1.2 Lines of sight between heads
Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces...
-
9.2.2(5)
(5) All controls in accessible units, sleeping rooms, and suites shall comply with 4.27....
-
11B-802.2.2.2 Lines of sight between heads
Where standing spectators are provided lines of sight over the shoulders and between the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair...
-
11B-802.2.2.2 Lines of sight between heads
Where standing spectators are provided lines of sight over the shoulders and between the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair...
-
Notification Devices
Guest rooms providing communication access are also subject to requirements for notification devices and telephones (806.3.2). Telephones must have volume control....
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
This expert panel also estimated that single-user toilet rooms with out-swinging doors would be used slightly less than once every other visit to a facility with such toilet rooms covered...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
This expert panel also estimated that single-user toilet rooms with out-swinging doors would be used slightly less than once every other visit to a facility with such toilet rooms covered...
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section....
-
4(2)
Except for design features, such as a loft or an area on a different level within a room (e.g., a sunken living room), changes in level greater than 1/2 inch are ramped or have other means...
-
M1
If a sign is provided at the toilet room entrance (e.g....
-
Question 17
Are the signs for the accessible restrooms and fitting rooms still readable and mounted next to the latch side of the door, at 5 feet to centerline of the sign?...
-
Using Qualified Interpreters
Many people with hearing and speech disabilities use sign language as their primary means of communication and use interpreters to communicate with people who don’t sign....
-
11B-809.10.5.2 Reinforcement for grab bars
At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
F213.3 Plumbing Fixtures and Accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with F213.2 shall comply with F213.3....
-
213.3 Plumbing Fixtures and Accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3....