The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
Search Results "Ground Transportation"
-
5.3.2.1 Size
-
Play areas. (Section-by-Section Analysis)
considered include, but are not limited to, the size of the public entity, geographical distance between sites, travel times to the sites, the number of sites, and availability of public transportation...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
required access to multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground...
-
Clear Floor or Ground Space: ADA Standard Section 902.4.1
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
-
§ 37.5(f)
(f) Private entities that are primarily engaged in the business of transporting people and whose operations affect commerce shall not discriminate against any individual on the basis of...
-
5.3.5 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1. ...
-
Section 37.37 Other Applications
Transportation service provided by public accommodations is viewed as being provided by private entities not primarily engaged in the business of transporting people....
-
5.1.9 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4. ...
-
§ 37.9 Standards for accessible transportation facilities
[71 FR 63265, Oct. 30, 2006]
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
1008.2.6.2 Use Zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
4. Obstructions
Transportation entities are not required to pick up passengers with disabilities at nondesignated locations....
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
3.4.6 Surface
The surface of each viewing area shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
502.4 Floor or Ground Surfaces
Parking spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not...