Provide handrails on each side of the ramps at the following locations:...
Search Results "Flared Side"
-
Ramps
-
Figure M2: M301.4 Lift Compatibility
(at Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position)...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
Parking Spaces [4.6.3]
For vans with side-mounted lifts, a combined width of almost 17 feet is often needed for the deployment and use of side-mounted lifts; ADAAG requires at least 16 feet....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
Clear Ground Space [1011.2]
Fire rings, grills, fireplaces, and woodstoves 48 by 48 inches on all usable sides of a fire ring, grill, fireplace, and woodstove....
-
Ramps M303:3.3, 3.3.1, 3.3.2
Ramps with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the...
-
308 Reach Ranges
In the final rule, the maximum side reach has been lowered to the height specified for forward reaches....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
R409.2 Where Required
Handrails shall be provided on both sides of ramps and stairways....
-
Clarification on Standard Roll-In Shower Compliance
with a full opening width on the long side."...
-
Where must curb ramps be provided?
Curb ramps must be located to ensure a person with a mobility disability can travel from a sidewalk on one side of the street, over or through any curbs or traffic islands, to the sidewalk...
-
Cross Slope [1017.7.2]
Cross slope is the side-to-side slope of a trail tread....
-
1. & 2. Sidewalk Slope
.: slopes tilting side to side) less than 1:50 (critical dimension of ´" or less) [sic] so persons who use wheelchairs can conveniently negotiate the routes?...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
4.34.6.8* REFRIGERATOR/FREEZER
Provision shall be made for refrigerators which are: (1) Of the vertical side-by-side refrigerator/freezer type; or (2) Of the over-and-under type and meet the following requirements...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
410.6 Doors and Gates
Side doors and gates shall provide a clear width 42 inches (1065 mm) minimum....
-
Imaging bed
A component of diagnostic scanning equipment that accommodates patients in supine, prone, or side-lying positions....