those features that are necessary to provide access to services, programs, and activities -- including elevators and lifts, curb ramps at intersections, accessible parking spaces, ramps to building...
Search Results "Building Permit"
-
3. Maintenance of Accessible Features
-
II-6.3100 General principles
frequented by the public or which "may result in employment ... of physically handicapped persons" (§1). 2) Equivalent facilitation ADAAG: Departures from particular standards are permitted...
-
1511.9.6 Accessibility and egress
ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "This new code section was adopted...
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
-
ASME: ADA Standard Section 105.2.2
Section 105.2.2 of the ADA Standards cover references to the American Society of Mechanical Engineers (ASME) standards.
-
General: ADA Standard Section 202.1
Section 202.1 of the ADA Standards covers the most current information on additions and alterations to existing buildings and facilities.
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
11B-505.6 Gripping surface
Exceptions: Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along...
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.
-
11B-505.6 Gripping surface
Exceptions: Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along...
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
-
11B-1008.2.4.2 Elevated
Exceptions: The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (813 mm) minimum for a distance of 24 inches (610...
-
11B-1008.2.4.2 Elevated
Exceptions: The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (813 mm) minimum for a distance of 24 inches (610...
-
11B-213.3 Plumbing fixtures and accessories
The 2022 California Plumbing Code (CPC), Table 422.1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-213.3 Plumbing fixtures and accessories
The 2016 California Plumbing Code (CPC), Table 422.1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
Knee and Toe Clearance: ADA Standard Section 305.4
Section 305.4 covers the current ADA Standards for knee and toe clearance included in clear floor space.
-
ELEMENT
[DSA-AC] An architectural or mechanical component of a building, facility, space or site....
-
Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
OCCUPANT LOAD
The number of persons for which the means of egress of a building or portion thereof is designed....
-
ELEMENT
[DSA-AC] An architectural or mechanical component of a building, facility, space or site....