In-swinging doors must clear fixture clearances and door clearances must clear the water closet fixture (verify toilet length)....
Search Results "Bedside Clearance"
Commonly Searched Documents
-
Recessed Lavatories
-
Water Closet Clear Floor Space in Toilet Compartments
Water closets not in compartments require clearance that is at least 60 inches wide and 56 inches deep....
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
§ 38.25(c) Door height
For vehicles in excess of 22 feet in length, the overhead clearance between the top of the door opening and the raised lift platform, or highest point of a ramp, shall be a minimum of 68...
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
Water Closet Clear Floor Space
Clearance requirements for water closets are covered in section 604.3....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base (proposed...
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
Recessed Objects
Elements, such as wheelchair accessible drinking fountains, must provide a knee clearance of at least 27”....
-
Floor and Ground Surfaces
apply to: interior and exterior accessible routes, including walking surfaces, ramps, elevators, and lifts stairways that are part of a means of egress required clearances...
-
R210.3 Shared Use Paths
The AASHTO Guide recommends 10 feet vertical clearance along shared use paths, and 8 feet minimum vertical clearance in constrained areas....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
FIGURE INDEX
in an Alcove, Forward Approach Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach Figure 306.2 Toe Clearance Figure 306.3 Knee Clearance Figure...
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
Paperwork Reduction Act
This rule imposes no new information reporting or recordkeeping necessitating clearance by the Office of Management and Budget....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
809.2.2 Turning Space
It is generally acceptable to use required clearances to provide wheelchair turning space....