Accessibility complying with Section 11B-703.7.2.1, indicating the accessible route to the nearest accessible entrance shall be provided at junctions when the accessible route diverges from...
Search Results "Assurances from Contractors"
-
11B-216.6 Entrances
-
11B-208.3.1 General
Parking spaces complying with Section 11B-502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with Section...
-
11B-208.3.1 General
Parking spaces complying with Section 11B-502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with Section...
-
11B-216.6 Entrances
Accessibility complying with Section 11B-703.7.2.1, indicating the accessible route to the nearest accessible entrance shall be provided at junctions when the accessible route diverges from...
-
General: ADA Standard Section 502.1
Section 502.1 of the ADA Standards covers information in the current ADA Standards for accessible parking spaces.
-
Nosings: ADA Standard Section 504.5
Section 504.5 covers the current ADA Standards for stair nosings.
-
Refrigerator/Freezer: ADA Standard Section 804.6.6
space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset 24 inches (610 mm) maximum from...
-
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
To see Chapter 3, consult California Code of Regulations, Title 24, Part 2 - 2022 California Building Code (2022 CBC), available for purchase from International Code Council (http://www.iccsafe.org...
-
11B-804.6.6 Refrigerator/freezer
space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset 24 inches (610 mm) maximum from...
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
11B-804.6.6 Refrigerator/freezer
space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset 24 inches (610 mm) maximum from...
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
To see Chapter 3, consult California Code of Regulations, Title 24, Part 2 - 2025 California Building Code (2025 CBC), available for purchase from International Code Council (http://www.iccsafe.org...
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
3.10 Cinemark 22, 2600 West Avenue I, Lancaster, California
3.10 Cinemark 22 2600 West Avenue I, Lancaster, California - In Auditorium 10, the four (4) wheelchair spaces shall be located one row further back in the auditorium from their current...
-
3.8 Cinemark at Valley View, 6001 Canal Road, Valley View, Ohio
3.8 Cinemark at Valley View 6001 Canal Road, Valley View, Ohio - In Auditorium 15, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium from their...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
2010 California Standards for Accessible Design (excerpts relating to Safe Harbors only)
2010 California Standards for Accessible Design ETA Editor's Note This document contains excerpts from the 2010 California Building Code, relating to Safe Harbors, and should not...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
M302.2.4 Transfer Sides (Section-by-Section Analysis)
In the MDE NPRM, the transfer side provision for diagnostic equipment used by patients in the seated position required transfer surfaces to have the option to transfer from a mobility device...
-
II. ENFORCING THE ADA PART 1
The Department's architect met with FEMA officials and contractors to discuss strategies for improving accessible housing options for people with mobility disabilities....
-
General rule on reservations. (Section-by-Section Analysis)
The ability to obtain information about accessible guest rooms, to make reservations for accessible guest rooms in the same manner as other guests, and to be assured of an accessible room...