Section 604.3 covers the current ADA Standards for clearances around water closets and in toilet compartments.
Search Results "Space Limitation"
-
Clearance: ADA Standard Section 604.3
-
11B-802.3 Companion seats
Companion seats shall comply with Section 11B-802.3.
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
11B-802.3 Companion seats
Companion seats shall comply with Section 11B-802.3.
- citEcar ADA Electric Shuttle 11P 1WC
- citEcar ADA Enclosed Shuttle 11P 1WC
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
-
F245.2.5.2 Parking Spaces
Where provided, at least one parking space shall comply with 1012.3, 1012.4, and 1012.5....
-
Sections 35.108(d)(1)(viii) and 36.105(d)(1)(viii)—Determination Made Without Regard to the Ameliorative Effects of Mitigating Measures
However, the beneficial effects of ordinary eyeglasses or contact lenses should be considered when determining whether an impairment substantially limits a major life activity....
-
602.2 Clear Floor Space
602.2 Clear Floor Space. Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
603.2.1 Turning Space
603.2.1 Turning Space. Turning space complying with 304 shall be provided within the room....
-
612.3 Turning Space
612.3 Turning Space. A turning space complying with 304 shall be provided within saunas and steam rooms....
-
11B-605.5.2 Maneuvering clearance
A minimum 66 inches (1676 mm) wide and 66 inches (1676 mm) deep maneuvering space shall be provided in front of the urinal....
-
11B-605.5.2 Maneuvering clearance
A minimum 66 inches (1676 mm) wide and 66 inches (1676 mm) deep maneuvering space shall be provided in front of the urinal....
-
1016.8.4 Turning Space
This section requires a turning space complying with 304.2.3 of the Architectural Barriers Act Accessibility Guidelines where resting intervals are provided adjacent to an outdoor recreation...
-
703.2.7 Character Spacing
703.2.7 Character Spacing. Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
-
4.4.4 Clear Floor or Ground Space
A clear floor or ground space of 36 inches (915 mm) by 48 inches (1220 mm) shall be located at an end the bench with one side of the space adjoining an accessible route, outdoor recreation...
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....