Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
Search Results "Non-Positive Shut Off"
Commonly Searched Documents
-
11B-703.8.9 Height above floor
-
Sloped Entries: ADA Standard Section 1009.3
Providing an aquatic wheelchair made of non-corrosive materials and designed for access into the water will protect the water from contamination and avoid damage to personal wheelchairs...
-
11B-232.5.1 Cubicles and counters
Exception: The inmate or detainee side of cubicles or counters at non-contact visiting areas not serving holding cells or housing cells required to comply with Section 11B-232 shall not...
-
Reassignment
Therefore, the employee is not qualified for this position....
-
18. Does an employer have to hold open an employee's job as a reasonable accommodation?
An employee with a disability who is granted leave as a reasonable accommodation is entitled to return to his/her same position unless the employer demonstrates that holding open the position...
-
Accessible Medical Equipment
We provide participants transfer assistance on and off of equipment (this includes use of lift equipment when needed). ...
-
11B-209.5 Mechanical access parking garages
Mechanical access parking garages shall provide at least one passenger loading zone complying with Section 11B-503 at vehicle drop-off and vehicle pick-up areas. ...
-
§ 38.159(c)(4) Ramp barriers
Each side of the ramp shall have barriers at least 2 inches (50 mm) high to prevent mobility aid wheels from slipping off....
-
§ 38.95(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
§ 38.63(b) Exception
Between-car barriers are not required where platform screens are provided which close off the platform edge and open only when trains are correctly aligned with the doors....
-
§ 38.125(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
§ 38.83(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
DRIVEWAY
A vehicular way providing access between a public way and a building, parking facility, or other off-street area. A driveway may provide access to drive aisles in a parking facility....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
406.2.2 Clear height
" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular routes to these spaces, and passenger drop-off...
- Damixa Clover Easy Kitchen Mixer with X-Change Connector Kit 60027
-
T603.2 Orientation
Wheelchair securement systems shall secure the wheelchair so that the occupant faces the front of the non-rail vehicle....
-
T404.3 Ramps and Bridgeplates
Where the space between the floor of non-rail vehicles and a boarding platform is greater than 2 inches (51 mm) horizontally or 5/8 inch (16 mm) vertically when measured at 50 percent passenger...
-
11B-503.2 Vehicle pull-up space
Passenger drop-off and loading zones shall provide a vehicular pull-up space 96 inches (2438 mm) wide minimum and 20 feet (6096 mm) long minimum....
-
B4. Vertical Clearance
Is the vertical height for the vehicle route to the loading zone, the drop off area, and the exit at least 114 inches (9 feet 6 inches) in height?...
-
11B-503.2 Vehicle pull-up space
Passenger drop-off and loading zones shall provide a vehicular pull-up space 96 inches (2438 mm) wide minimum and 20 feet (6096 mm) long minimum. ...
-
11B-503.2 Vehicle pull-up space
Passenger drop-off and loading zones shall provide a vehicular pull-up space 96 inches (2438 mm) wide minimum and 20 feet (6096 mm) long minimum....
-
Section 1193.37 Information pass-through [1193.27 in the NPRM] (Section-by-Section Analysis)
Moreover, some technologies operate through "compression" of one sort or another and cannot be turned on or off, as suggested by the NPRM preamble....
- The Challenges EV Charging for People with Disabilities