Accessible Routes on the Playing Surface The surface of the accessible route must be stable, firm and slip resistant....
Search Results "Ground Level Play Component"
-
Accessible Routes on the Playing Surface
- Morgan's Wonderland - San Antonio, Texas
-
1132A.4, Item 1
Changes in level shall comply with Section 1131A....
-
1132A.4, Item 1
Changes in level shall comply with Section 1131A....
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
504.4 Tread Surface
Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface....
-
504.4 Tread Surface
Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface....
-
§ 38.83(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
Door Swing: ADA Standard Section 803.3
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
§ 38.159(c)(3) Ramp threshold
Changes in level between 1/4 inch (6.5 mm) and 1/2 inch (13 mm) shall be beveled with a slope no greater than 1:2....
-
A4.28.2 Audible Alarms
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
A4.28.2 AUDIBLE ALARMS
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
Wet Conditions [§405.10]
Wet Conditions [§405.10] Landings subject to wet conditions must be designed to prevent the accumulation of water. Landings are permitted slopes not steeper than 1:48 to allow for...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
504.4 Tread Surface
Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface....
-
About this Study
Acceptable Surfacing System Requirements Stabilizing binders needed to be applied on-site or mixed with the EWF no longer than an hour prior to placement on the ground surface....
-
302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10....
-
11B-233.3.1.2.3 Ground floors above grade
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect. The requirements in this section were previously found in...
-
302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10....
-
1011.2.4 Openings
This section requires openings in the clear ground space such as drainage grates to not allow passage of a sphere more than 1/2 inch in diameter....
-
5.1.6 Clear Floor or Ground Space
A clear floor or ground space at least 36 inches (915 mm) by 48 inches (1220 mm) shall be provided parallel to the entrance to the camp shelter....
- Choosing Level Size