About Commercial Thresholds Pemko manufactures thresholds in several materials to meet customer needs. Extruded Aluminum thresholds are manufactured of tempered aluminum, 6063-T6....
Search Results "Ground Level Play Component"
Commonly Searched Documents
- PEMKO 5 9/16" Thermal Barrier Threshold No. 273x292-FGPK
- PEMKO 8 1/8" Thermal Barrier Threshold No. 254X4-FG
-
Wheelchair accessible seating is required. At least one percent of the seating must be wheelchair seating locations.
Each wheelchair seating location is an open, level space that accommodates one person using a wheelchair and has a smooth, stable, and slip-resistant surface....
-
Surface
The top layer of a trail.
-
4.5.4 Gratings
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g)). If gratings have elongated openings,...
-
4.7.4 Surface
Surfaces of curb ramps shall comply with 4.5.
-
4.7.4 SURFACE
Surfaces of curb ramps shall comply with 4.5.
-
4.5.4 GRATINGS
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g)). If gratings have elongated openings,...
-
Boat Slips: ADA Standard Section 1003.2.1
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
Carpet [4.5.3]
Studies show that the level of roll resistance of carpet, even low-pile carpet that is properly secured, is considerably higher than the roll resistance of firmer surfaces such as concrete...
-
§ 38.125(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
-
3.2.4 Slope
The ground surface in all camp living areas shall have a slope of no more than 1:48 (2 percent) in any direction. Exception....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3...
-
4.7.7 Water Spouts
Water spouts shall be located in the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the clear floor or ground...
-
What proportion of the population could negotiate these surfaces?
Energy consumption, level of difficulty rating and rating of perceived exertion were evaluated to determine the proportion of our subjects who considered each surface to be “accessible.”...
- Stabila, Inc. Magnetic Tech Digital Electronic Level Type 96M-2
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
- StormPave Permeable Clay Pavers
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. EXCEPTION: Where the surface is other...
-
16. In § 38.111
§ 38.111 [Amended] 16. In § 38.111,
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. EXCEPTION: Where the surface is other...