Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
Search Results "Floor Button"
Commonly Searched Documents
-
11B-809.9.1 Clear floor space
-
§ 38.159(c)(5) Slope
If the height of the vehicle floor from which the ramp is deployed is 3 inches (75 mm) or less above a 6 inch (150 mm) curb, a maximum slope of 1:4 is permitted; if the height of the vehicle...
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
- Inpro Corporation JointMaster® 925 Fire Barrier System Expansion Joint Systems
-
Accessible Sidewalks 4: Pedestrians who are Blind
Requires the Registered User plan or above. Login!
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture....
-
606.2 Clear Floor Space
606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches....
-
Station platforms
Station platforms must be coordinated with the vehicle floor height. (DOT ADA Standard 810.5.3.)...
-
Location: ADA Standard Section 703.4.2
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
F231.3 Holding Cells
Where provided, central holding cells and court-floor holding cells shall comply with F231.3....
-
231.3 Holding Cells
Where provided, central holding cells and court-floor holding cells shall comply with 231.3....
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
access to multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor...
-
11B-231.3 Holding cells
Where provided, central holding cells and court-floor holding cells shall comply with Section 11B-231.3. ...
-
11B-231.3 Holding cells
Where provided, central holding cells and court-floor holding cells shall comply with Section 11B-231.3....
-
11B-231.3 Holding cells
Where provided, central holding cells and court-floor holding cells shall comply with Section 11B-231.3....
-
1. Accessible toilet
Accessible toilet with rear and side grab bars, clear floor space for wheelchair transfer, and an accessible flush valve....
-
231.3 Holding Cells
Where provided, central holding cells and court-floor holding cells shall comply with 231.3....
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....