inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with the front end positioned 24 inches (610 mm) minimum in front of the water closet...
Search Results "Closet Door"
Commonly Searched Documents
-
11B-604.5.1 Side wall
-
H23
Is the door to the toilet stall located diagonally opposite, not directly in front of, the toilet or on the opposite side wall from the wall with the long grab bar?...
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
206.5.4 Residential Dwelling Units
In residential dwelling units required to provide mobility features complying with 809.2 through 809.4, all doors and doorways providing user passage shall comply with 404....
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
D2. Clear Passage
Does at least one door or one side of a double leaf door at the accessible entrance provide at least 32 inches clear passage width when the door is open 90 degrees?...
- Oatey Level Fit Offset Closet Flange Metal Ring 43804 - PVC Bulk
- Oatey Level Fit Offset Closet Flange Metal Ring 43500 - ABS 15150
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
D6. Vestibule Clear Floor Space
[ADA Stds 4.13.7] Yes _____ No _____ If No, leave the inner door open or remove inner door, add power operators to both doors so they open at the same time or, modify the vestibule...
-
§ 38.93(a)(1)
(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided...
-
11B-604.5.1 Side wall
12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with the front end positioned 24 inches (610 mm) minimum in front of the water closet...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
4(4)
(4) Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch....
- Whitehall Mfg. WH2142W2 Ligature-Resistant Toilet Wall Supply On-Floor Wall Waste
- Whitehall Mfg. Ligature Resistant Toilet Top Supply On-Floor
- Whitehall Mfg. WH2142T2 Ligature Resistant Toilet Top Supply On-Floor Wall Waste
- ADAEZ Pro Plus Automatic Door Opener Installation Video
-
D4
On the latch, pull side of the door, is there at least 18 inches clearance provided if the door is not automatic or power-operated?...
-
Willoughby Industries ASETWS-1490-FM-HC Ligature-Resistant Floor Mounted Siphon Jet Water Closet