Section 304.2 covers the current ADA Standards for the ground surfaces of a turning space.
Search Results "Wheelchair Space (Transportation)"
-
Floor or Ground Surfaces: ADA Standard Section 304.2
-
10.3.2(5)
commercial, retail, or residential facilities shall, to the maximum extent feasible, have an accessible route complying with 4.3 from the point of connection to boarding platforms and all transportation...
-
11B-218 Transportation facilities.
[See subsections ...]
-
11B-218 Transportation facilities
[See subsections ...]
-
106.5 Defined Terms, F106.5 Defined Terms
The term is defined to mean a single or multiple section prefabricated structure that is transportable on a single transport vehicle and that can be set-up and installed on a temporary site...
-
Exterior Spaces: ADA Standard Section 806.2.2
Exterior spaces, including patios, terraces and balconies, that serve the guest room shall be accessible. [S.H. 9.2.2(6)(d)]...
-
Performance Areas
route must connect stages and other performance areas directly to seating areas where they are directly connected by a circulation path as well as to dressing rooms and other ancillary spaces...
-
§382.129 What other requirements apply when passengers' wheelchairs, other mobility aids, and other assistive devices must be disassembled for stowage?
[See subsections ...]
-
11B-234.3 Minimum number
Amusement rides shall provide at least one wheelchair space complying with Section 11B-1002.4, or at least one amusement ride seat designed for transfer complying with Section 11B-1002.5...
-
11B-234.3 Minimum number
Amusement rides shall provide at least one wheelchair space complying with Section 11B-1002.4, or at least one amusement ride seat designed for transfer complying with Section 11B-1002.5...
-
11B-234.3 Minimum number
Amusement rides shall provide at least one wheelchair space complying with Section 11B-1002.4, or at least one amusement ride seat designed for transfer complying with Section 11B-1002.5...
-
III-7.5180 Assembly areas
This section specifies the number of wheelchair seating spaces and types and numbers of assistive listening systems required in assembly areas. 1) Wheelchair seating: Requirements for...
-
10.1 General
Every station, bus stop, bus stop pad, terminal, building or other transportation facility, shall comply with the applicable provisions of 4.1 through 4.35, sections 5 through 9, and the...
-
Wheelchairs and other power-driven mobility devices.
The basic Segway® model is a two-wheeled, gyroscopically stabilized, battery-powered personal transportation device. ...
-
12162(e)(2)(A)(ii)(I) Intercity rail
(I) Intercity rail All stations in the intercity rail transportation system shall be made readily accessible to and usable by individuals with disabilities, including individuals who...
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height.
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations The Committee recommends a two-inch high edge protection on the back of the...
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope. Raised platforms should have a ramp with slopes that do not exceed the following: Rise 0 to 1 ½ inches – 1:2 Slope Rise >1 ½ to 2 ½ inches – 1:8...
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides. A minimum 2 inch high edge protection must be provided on both sides of the platform for double ramped entry...
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides. A 2 inch high edge protection must be provided on the back of the platform, opposite the entry...
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less...
-
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations The Committee recommends a minimum two-inch high edge protection on both sides of the...