5.2 Transfer Surface Size Recommendations
Search Results "Side Grab Bar"
Commonly Searched Documents
-
5.2 Transfer Surface Size Recommendations
-
M301.2.2 Size
The transfer surface shall be 30 inches (760 mm) wide minimum and 15 inches (381mm) deep minimum. Advisory M301.2.2 Size. The size requirements in this section apply only to the...
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
606.2 Clear Floor Space
A parallel approach complying with 305 shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided and to wet bars. 2....
-
606.2 Clear Floor Space
A parallel approach complying with 305 shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided and to wet bars. 2....
-
M301.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum....
-
Single-User Toilet Rooms: No Side Transfer Space
Single-User Toilet Rooms: No Side Transfer Space On single plumbing walls, lavatories can overlap water closet clear floor space although this precludes side transfers....
- AJW Architectural Products UG130-Railing UG130X-Y108 108" Exposed Flange, 1.5" Diameter Grab Bar, Peened Grip - Configuration Y
-
M301.3.2 Leg Supports
Where stirrups are provided, leg supports shall also be provided and shall comply with M305.4.
-
M305.4 Leg Supports (Section-by-Section Analysis)
As discussed above in Section V.C.3.b (Section-by-Section Analysis – M301.3.2) and Section V.C.7.b (Section-by-Section Analysis – M302.3.2), the technical requirements for leg...
-
M301.2.1, M302.2.1 Transfer Height
M301.2.1, M302.2.1 Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm)...
-
iv. Lifts
iv. Lifts Medical providers may need lifts to transfer some patients with mobility disabilities safely to examination or treatment tables or chairs or to gurneys or hospital beds....
-
M301.3.2 Stirrups
Where stirrups are provided, they shall provide a method of supporting, positioning, and securing the patient’s legs.
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying...
-
A4.26.2 Size and Spacing of Grab Bars and Handrails
This specification allows for alternate shapes of handrails as long as they allow an opposing grip similar to that provided by a circular section of 1‒1/4 in to 1‒1/2 in (32 mm to 38...
-
A4.26.2 SIZE AND SPACING OF GRAB BARS AND HANDRAILS
This specification allows for alternate shapes of handrails as long as they allow an opposing grips similar to that provided by a circular section of 1-1/4 in to 1-1/2 in (32 mm to...
-
17 Inch Low Height
Impact of Transfer Setup on the Performance of Independent Transfers: Final Report provides an analysis of the effect of height, horizontal gap, placement of armrests, and placement of grab...
-
Regulatory Impact Analysis.
proposed requirements for each of the following eight existing elements will exceed monetized benefits by more than $100 million when using the 1991 Standards as the comparative baseline: Side...
- Georgia-Pacific Compact® Side-By-Side Double Roll Bathroom Tissue Dispenser 56798
-
Side guard protocol
Side guard protocol: From initial setup, two side guards adjusted 6” (15.2 cm) higher than the subject’s WMD seat were attached, and subjects were asked to perform a level height transfer...
-
1002.4.4.2 Side Entry
1002.4.4.2 Side Entry....
-
11B-608.5.3 Alternate roll-in type shower compartments
The controls, faucets, and shower spray units shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor....