Section 232.5.1 covers scoping requirements in the current ADA Standards for cubicles and counters.
Search Results "Pull Side"
Commonly Searched Documents
-
Cubicles and Counters: ADA Standard Section 232.5.1
-
11B-604.8.2.3 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
3.3.16 Door Use
Push Pull Push Pull Total Sample size Subtotal - completed the task ...
-
11B-812.7.1 Location
Access aisles at vehicle spaces shall not overlap the vehicular way and may be placed on either side of the vehicle space they serve except for van accessible spaces which shall have access...
-
Clarification on Standard Roll-In Shower Compliance
with a full opening width on the long side."...
-
11B-1005.3 Edge protection
pier or platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs or other mobility devices to pull...
-
11B-231.4.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....
- Grohe Ladylux3 Café Touch Pull-Down Kitchen Faucet with Touch Technology
-
Beds: ADA Standard Section 807.2.3
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
Bradley Towel Dispenser 252 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-232.5.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
Location: ADA Standard Section 604.9.1
Section 604.9.1 covers the current ADA Standards for the mounting location of children's use water closets.
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
§382.65(c)(2)
(2) The chair must be designed to be compatible with the maneuvering space, aisle width, and seat height of the aircraft on which it is to be used, and to be easily pushed, pulled, and turned...
-
Must operable parts be usable with a closed fist?
Many types of operable parts, such as pull handles, satisfy the requirements even though they may not be operable with a closed fist....
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
-
Polling places that cannot be remediated with temporary measures:
Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2)....
-
Horizontal Dispersion: ADA Standard Section 221.2.3.1
Section 221.2.3.1 covers scoping requirements in the current ADA Standards for horizontal Dispersion in assembly areas.
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
Forward Reach [4.2.5]
Since the forward reach over an obstruction is limited by how far a person using a wheelchair can pull up below it, the depth of reach cannot exceed the amount of usable clear floor space...
-
ELKAY Filtered EZH2O® Bottle Filling Station with Integral Soft Sides® Fountain LZWS-EDFP217K Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
39. Must an employer provide a reasonable accommodation that is needed because of the side effects of medication or treatment related to the disability, or because of symptoms or other medical conditions resulting from the underlying disability?
The side effects caused by the medication that an employee must take because of the disability are limitations resulting from the disability....
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.