Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
Search Results "NFSI: National Floor Safety Institute"
Commonly Searched Documents
-
305.7 Maneuvering Clearance
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
1006.4 Weather Shelters
A clear floor or ground space 60 inches (1525 mm) minimum by 96 inches (2440 mm) minimum shall be provided within weather shelters....
-
Forward and Side Approaches
At most elements, clear floor space can be positioned for either a forward approach or a side approach....
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
1134A.6, Item 3
Floor space. ...
-
1134A.6, Item 3
Floor space....
-
§ 38.125(b)(6) Platform surface
(6) Platform surface. The lift platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant. The lift platform shall have a minimum clear width of...
-
1023.9 Stairway identification signs
A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more than three stories designating the floor level, the terminus of the top and bottom of...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
7(2)(b)(vii)
A minimum clear floor space 2'6" wide by 4'0" should be available outside the stall. (See Figure 7(d).)...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
222 and 803 Dressing, Fitting, and Locker Rooms
Some commenters stated that clothing and retail stores would have to expand and reconfigure accessible dressing, fitting and locker rooms to meet the changed provision for clear floor space...
-
Firmness, Stability, and Slip Resistance [§302.1]
Firmness, Stability, and Slip Resistance [§302.1] Accessible floor and ground surfaces must be stable, firm, and slip resistant....
-
810.5.3 Platform and Vehicle Floor Coordination
Advisory 810.5.3 Platform and Vehicle Floor Coordination....
-
11B-233.3.1.2.2 Non-elevator buildings
Ground floor residential dwelling units in non-elevator buildings shall be adaptable....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided....