(2) Where a building or facility is vacated and it is totally altered, then it shall be altered to comply with 4.1.1 to 4.1.5 of 4.1, Minimum Requirements, except to the extent where it...
Search Results "Maximum Extent Practicable"
Commonly Searched Documents
-
4.1.6(2)
-
Section 36.403 Alterations: Path of Travel
Another commenter asked that the safe harbor be revised to include pre-ADA facilities that have been made compliant with the 1991 Standards to the extent “readily achievable’’ or, in the...
-
Title III: Readily Achievable Barrier Removal
the elements in a business serving the public (public accommodation) do not comply with the requirements for those elements in the 1991 Standards, the elements must be modified, to the extent...
-
Seat Height: ADA Standard Section 1009.2.4
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
105.1 General
The standards listed in 105.2 are incorporated by reference in this document and are part of the requirements to the prescribed extent of each such reference....
-
§ 36.302(e)(3)
(3) Guarantee that an accessible guest room reserved through the reservations service will be held for the reserving customer during the reservation period to the same extent that it guarantees...
-
Sec.36.304(g)(2)
(2) To the extent that relevant standards for alterations are not provided in subpart D of this part, then the requirements of Sec.36.304 shall not be interpreted to exceed the standards...
-
Sec.36.304(f) Selling or serving space
The rearrangement of temporary or movable structures, such as furniture, equipment, and display racks is not readily achievable to the extent that it results in a significant loss of selling...
-
§ 36.304(f) Selling or serving space
The rearrangement of temporary or movable structures, such as furniture, equipment, and display racks is not readily achievable to the extent that it results in a significant loss of selling...
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
Grab Bars: ADA Standard Section 1009.5.7
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-1009.2.1 Pool lift location
Pool lifts shall be located where the water level is 36 inches (914 mm) minimum and 48 inches (1219 mm) maximum. [2010 ADA Standards] 1009.2.1 Pool Lift Location....
-
11B-703.4.1 Height above finish floor or ground
characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524 mm) maximum...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
Structural Impracticability (Preamble, Section-by-Section Analysis)
With respect to the structural impracticability exception, a mixed-use facility could not take advantage of the Fair Housing exemption, to the extent that it is less stringent than the ADA...
-
1. Executive Summary
practicable....
-
Structural Impracticability (Section-By-Section Analysis and Response to Comments)
With respect to the structural impracticability exception, a mixed-use facility could not take advantage of the Fair Housing exemption, to the extent that it is less stringent than the ADA...
-
Location
Devices must be located a minimum of 3m (10 feet) apart, no more than 3m (10 feet) maximum from the curb line (and closer, if possible), and between the curb ramp landing and the outside...
-
Executive Orders 12866 and 13563
difficult to quantify); (2) tailor its regulations to impose the least burden on society, consistent with obtaining regulatory objectives, taking into account, among other things, and to the extent...
-
Requirement to block accessible guest room reservations. (Section-by-Section Analysis)
a public accommodation that owns, leases (or leases to), or operates a place of lodging to guarantee accessible guest rooms that are reserved through a reservations service to the same extent...